Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Six-dimensional real and reciprocal space small-angle X-ray scattering tomography

Abstract

When used in combination with raster scanning, small-angle X-ray scattering (SAXS) has proven to be a valuable imaging technique of the nanoscale1, for example of bone, teeth and brain matter2,3,4,5. Although two-dimensional projection imaging has been used to characterize various materials successfully, its three-dimensional extension, SAXS computed tomography, poses substantial challenges, which have yet to be overcome. Previous work6,7,8,9,10,11 using SAXS computed tomography was unable to preserve oriented SAXS signals during reconstruction. Here we present a solution to this problem and obtain a complete SAXS computed tomography, which preserves oriented scattering information. By introducing virtual tomography axes, we take advantage of the two-dimensional SAXS information recorded on an area detector and use it to reconstruct the full three-dimensional scattering distribution in reciprocal space for each voxel of the three-dimensional object in real space. The presented method could be of interest for a combined six-dimensional real and reciprocal space characterization of mesoscopic materials with hierarchically structured features with length scales ranging from a few nanometres to a few millimetres—for example, biomaterials such as bone or teeth, or functional materials such as fuel-cell or battery components.

This is a preview of subscription content, access via your institution

Access options

Rent or buy this article

Prices vary by article type

from$1.95

to$39.95

Prices may be subject to local taxes which are calculated during checkout

Figure 1: Experimental set-up and raster-scanning technique.
Figure 2: Virtual SAXS patterns extracted from the reconstructed 3D volume.
Figure 3: 3D visualization of collagen fibre orientation within the tooth sample.

Similar content being viewed by others

References

  1. Fratzl, P., Jakob, H. F., Rinnerthaler, S., Roschger, P. & Klaushofer, K. Position-resolved small-angle X-ray scattering of complex biological materials. J. Appl. Cryst. 30, 765–769 (1997)

    Article  CAS  Google Scholar 

  2. Fratzl, P., Schreiber, S. & Boyde, A. Characterization of bone mineral crystals in horse radius by small-angle X-ray scattering. Calcif. Tissue Int. 58, 341–346 (1996)

    Article  CAS  Google Scholar 

  3. Kinney, J. H., Pople, J. A., Marshall, G. W. & Marshall, S. J. Collagen orientation and crystallite size in human dentin: a small angle X-ray scattering study. Calcif. Tissue Int. 69, 31–37 (2001)

    Article  CAS  Google Scholar 

  4. Falzon, G. et al. Myelin structure is a key difference in the x-ray scattering signature between meningioma, schwannoma and glioblastoma multiforme. Phys. Med. Biol. 52, 6543–6553 (2007)

    Article  CAS  Google Scholar 

  5. De Felici, M. et al. Structural characterization of the human cerebral myelin sheath by small angle x-ray scattering. Phys. Med. Biol. 53, 5675–5688 (2008)

    Article  CAS  Google Scholar 

  6. Schroer, C. G. et al. Mapping the local nanostructure inside a specimen by tomographic small-angle x-ray scattering. Appl. Phys. Lett. 88, 164102 (2006)

    Article  ADS  Google Scholar 

  7. Stribeck, N. et al. Volume-resolved nanostructure survey of a polymer part by means of SAXS microtomography. Macromol. Chem. Phys. 207, 1139–1149 (2006)

    Article  CAS  Google Scholar 

  8. Stribeck, N. et al. SAXS-fiber computer tomography. Method enhancement and analysis of microfibrillar-reinforced composite precursors from PEBA and PET. Macromolecules 41, 7637–7647 (2008)

    Article  CAS  ADS  Google Scholar 

  9. Feldkamp, J. M. et al. Recent developments in tomographic small-angle X-ray scattering. Phys. Status Solidi A 206, 1723–1726 (2009)

    Article  CAS  ADS  Google Scholar 

  10. Jensen, T. H. et al. Brain tumor imaging using small-angle x-ray scattering tomography. Phys. Med. Biol. 56, 1717–1726 (2011)

    Article  Google Scholar 

  11. Jensen, T. H. et al. Molecular X-ray computed tomography of myelin in a rat brain. Neuroimage 57, 124–129 (2011)

    Article  CAS  Google Scholar 

  12. Rinnerthaler, S. et al. Scanning small angle X-ray scattering analysis of human bone sections. Calcif. Tissue Int. 64, 422–429 (1999)

    Article  CAS  Google Scholar 

  13. Boote, C., Dennis, S. & Meek, K. Spatial mapping of collagen fibril organisation in primate cornea—an X-ray diffraction investigation. J. Struct. Biol. 146, 359–367 (2004)

    Article  CAS  Google Scholar 

  14. Moger, C. J. et al. Regional variations of collagen orientation in normal and diseased articular cartilage and subchondral bone determined using small angle X-ray scattering (SAXS). Osteoarthr. Cartilage 15, 682–687 (2007)

    Article  CAS  Google Scholar 

  15. Bunk, O. et al. Multimodal x-ray scatter imaging. New J. Phys. 11, 123016 (2009)

    Article  ADS  Google Scholar 

  16. Meek, K. M. & Boote, C. The use of X-ray scattering techniques to quantify the orientation and distribution of collagen in the corneal stroma. Prog. Retin. Eye Res. 28, 369–392 (2009)

    Article  CAS  Google Scholar 

  17. Märten, A., Fratzl, P., Paris, O. & Zaslansky, P. On the mineral in collagen of human crown dentine. Biomaterials 31, 5479–5490 (2010)

    Article  Google Scholar 

  18. Bossa, N. et al. Micro- and nano-X-ray computed-tomography: a step forward in the characterization of the pore network of a leached cement paste. Cement Concr. Res . 67, 138–147 (2015)

    Article  CAS  Google Scholar 

  19. Dierolf, M. et al. Ptychographic X-ray computed tomography at the nanoscale. Nature 467, 436–439 (2010)

    Article  CAS  ADS  Google Scholar 

  20. Gaiser, S., Deyhle, H., Bunk, O., White, S. N. & Müller, B. Understanding nano-anatomy of healthy and carious human teeth: a prerequisite for nanodentistry. Biointerphases 7, 4 (2012)

    Article  Google Scholar 

  21. Fratzl, P., Gupta, H., Paschalis, E. P. & Roschger, P. Structure and mechanical quality of the collagen-mineral nano-composite in bone. J. Mater. Chem. 14, 2115–2123 (2004)

    Article  CAS  Google Scholar 

  22. Eikenberry, E. F. et al. PILATUS: a two-dimensional X-ray detector for macromolecular crystallography. Nucl. Instrum. Methods Phys. Res. A 501, 260–266 (2003)

    Article  CAS  ADS  Google Scholar 

  23. Kieffer, J. & Karkoulis, D. PyFAI, a versatile library for azimuthal regrouping. J. Phys. Conf. Ser. 425, 202012 (2013)

    Article  Google Scholar 

  24. Sidky, E. Y., Kao, C.-M. & Pan, X. Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT. J. X-ray. Sci. Tech . 14, 119–139 (2006)

    Google Scholar 

  25. Feldkamp, J. Scanning Small-angle X-ray Scattering Tomography. Non-destructive Access to the Local Nanostructure. PhD thesis, Technische Universität Dresden (2009); http://nbn-resolving.de/urn:nbn:de:bsz:14-qucosa-24925

  26. Dinapoli, R. et al. EIGER: next generation single photon counting detector for X-ray applications. Nucl. Instrum. Methods Phys. Res. A 650, 79–83 (2011)

    Article  CAS  ADS  Google Scholar 

Download references

Acknowledgements

The SAXS experiments were performed at the cSAXS beamline of the Swiss Light Source (SLS) at the Paul Scherrer Institut (PSI), Villigen, Switzerland. We are grateful for travel support that was granted by the EU access program CALIPSO. We acknowledge financial support through the DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP) and the DFG Gottfried Wilhelm Leibniz program. P.Z. is grateful for funding of the DFG (German Research Foundation) through SPP1420. F.S. and C.J. thank the TUM Graduate School for support of their studies. F.P. acknowledges support through the TUM Institute for Advanced Studies (TUM-IAS). We thank A. Fehringer for developing the GPU projectors used for the reconstruction.

Author information

Authors and Affiliations

Authors

Contributions

F.P., M.B. and F.S. conceived the experiment. M.L. and M.G.-S. developed the sample stage used in the experiment. M.B., C.J., M.L., M.G.-S. and F.S. performed the experiment at cSAXS/PSI. P.Z. prepared the tooth sample. Data analysis was performed by F.S. with input and discussion from M.B., F.P. and P.Z. F.S. wrote the manuscript with contributions from all co-authors.

Corresponding authors

Correspondence to Florian Schaff, Martin Bech or Franz Pfeiffer.

Ethics declarations

Competing interests

The authors declare no competing financial interests.

Extended data figures and tables

Extended Data Figure 1 Comparison of measured and reconstructed values for one projection.

Left, reprojected q data for two different orientations (90° and 152°) is compared to the measured data. Right, azimuthal values for both the reconstructed and measured data are given for three select points, indicated by the dashed lines in the left panel. For the chosen |q| range, distinct collagen peaks are reconstructed correctly for points 1, 2 and 3 at around 15°, 0° and 90°, respectively. A good agreement between reconstruction and measurement is seen. Animations of this and further projections showing all q orientations are provided in Supplementary Videos 3, 4, 5.

Extended Data Figure 2 Coordinate system used for the experiment.

The sample orientation is described using three Euler angles θ, φ and ψ. With ψ = 90°, θ represents a tilt of the tomography axis around xlab and φ describes a rotation around this tilted axis. The sample is scanned along xlab and ylab, with a diffraction pattern collected at each point. The detector coordinates are given by dx and dy.

Extended Data Figure 3 Rotational invariance for a standard SAXS computed tomography with a vertical tomography axis.

a, Absorption image acquired from the diode data with two vertical slices marked. b, c, Rotational invariance as defined in the text for both slices. In both cases, rotational invariance is present for all pixels that correspond to scattering orientations parallel to the vertical rotation axis. The collagen fibres in the top part of the sample, shown in b, are mainly vertical. Owing to this symmetry, rotational invariance is also present for pixels not on the vertical axis. Without this symmetry, rotational invariance exists only for the vertical direction, as seen in c. The white bars in the lower half of the images are areas between the individual detector modules.

Extended Data Figure 4 Generalized rotational invariance.

a, b, Rotational invariance shown for different virtual tomography axes: (a) and (b). Radially integrated data are used. Compared to the standard case, shown in Extended Data Fig. 3, a line-wise integration is not possible in the general case. Instead, the standard deviation and mean are calculated from the projection-wise sum of all integrated SAXS patterns. A shift of the azimuthal angle so that the scattering orientation parallel to t is at 0° was applied. As can be seen, rotational invariance is also achieved in the general case for scattering orientations parallel to t.

Supplementary information

SAXS-patterns extracted from the reconstructed data at three different points.

All slices from top to bottom are shown. Animation of Figure 2. (MP4 1436 kb)

Three-dimensional visualization of collagen orientation and scattering strength within the tooth sample.

All slices of the sample from front to back are shown. Animation of Figure 3. (MP4 14801 kb)

A comparison of measured and reconstructed scattering intensities.

Azimuthal scattering orientations over 180° are shown for the projection recorded at θ = 0.0° and φ = 346.9°. Animation of Extended Figure 1. (MP4 1016 kb)

A comparison of measured and reconstructed scattering intensities.

Azimuthal scattering orientations over 180° are shown for the projection recorded at θ = -52.0° and φ = 216.9°. Animation of Extended Figure 1. (MP4 882 kb)

Comparison of measured and reconstructed scattering intensities.

Azimuthal scattering orientations over 180° are shown for the projection recorded at θ = -68.0° and φ = 120.0°. Animation of Extended Figure 1. (MP4 890 kb)

PowerPoint slides

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schaff, F., Bech, M., Zaslansky, P. et al. Six-dimensional real and reciprocal space small-angle X-ray scattering tomography. Nature 527, 353–356 (2015). https://doi.org/10.1038/nature16060

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/nature16060

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing