Access
To read this story in full you will need to login or make a payment (see right).
Letter
Nature 447, 694-697 (7 June 2007) | doi:10.1038/nature05897; Received 21 December 2006; Accepted 27 April 2007
Open Innovation Challenges
-
Fast Growth of Transformed Soybean Shoots
A method for accelerating growth of soybean shoots is desired.
-
Protect Enzyme from In Planta Degradation
A proposal for stable expression of an enzyme in corn seed is desired.
nature jobs
Postdoctoral Associate
- Thomas Jefferson University
- Philadelphia, Pennsylvannia, USA
Centre Director
- NCRA
- Pune, India
High-resolution, high-sensitivity NMR of nanolitre anisotropic samples by coil spinning
D. Sakellariou1, G. Le Goff2 & J.-F. Jacquinot2
- Laboratoire de Structure et Dynamique par Résonance Magnétique, Service de Chimie Moléculaire (Laboratoire Claude Fréjacques, CNRS URA 331) DSM/DRECAM/SCM, CEA Saclay, Gif-sur-Yvette 91191, France
- Service de Physique de l'Etat Condensé (CNRS URA 2464), DSM/DRECAM/SPEC, CEA Saclay, Gif-sur-Yvette 91191, France
Correspondence to: D. Sakellariou1 Correspondence and requests for materials should be addressed to D.S. (Email: dimitrios.sakellariou@cea.fr).
Abstract
Nuclear magnetic resonance (NMR) can probe the local structure and dynamic properties of liquids and solids, making it one of the most powerful and versatile analytical methods available today. However, its intrinsically low sensitivity precludes NMR analysis of very small samples—as frequently used when studying isotopically labelled biological molecules or advanced materials, or as preferred when conducting high-throughput screening of biological samples or 'lab-on-a-chip' studies. The sensitivity of NMR has been improved by using static micro-coils1, alternative detection schemes2, 3 and pre-polarization approaches4. But these strategies cannot be easily used in NMR experiments involving the fast sample spinning essential for obtaining well-resolved spectra5, 6 from non-liquid samples. Here we demonstrate that inductive coupling allows wireless transmission of radio-frequency pulses and the reception of NMR signals under fast spinning of both detector coil and sample. This enables NMR measurements characterized by an optimal filling factor, very high radio-frequency field amplitudes and enhanced sensitivity that increases with decreasing sample volume. Signals obtained for nanolitre-sized samples of organic powders and biological tissue increase by almost one order of magnitude (or, equivalently, are acquired two orders of magnitude faster), compared to standard NMR measurements. Our approach also offers optimal sensitivity when studying samples that need to be confined inside multiple safety barriers, such as radioactive materials. In principle, the co-rotation of a micrometre-sized detector coil with the sample and the use of inductive coupling (techniques that are at the heart of our method) should enable highly sensitive NMR measurements on any mass-limited sample that requires fast mechanical rotation to obtain well-resolved spectra. The method is easy to implement on a commercial NMR set-up and exhibits improved performance with miniaturization, and we accordingly expect that it will facilitate the development of novel solid-state NMR methodologies and find wide use in high-throughput chemical and biomedical analysis.
- Laboratoire de Structure et Dynamique par Résonance Magnétique, Service de Chimie Moléculaire (Laboratoire Claude Fréjacques, CNRS URA 331) DSM/DRECAM/SCM, CEA Saclay, Gif-sur-Yvette 91191, France
- Service de Physique de l'Etat Condensé (CNRS URA 2464), DSM/DRECAM/SPEC, CEA Saclay, Gif-sur-Yvette 91191, France
Correspondence to: D. Sakellariou1 Correspondence and requests for materials should be addressed to D.S. (Email: dimitrios.sakellariou@cea.fr).
To read this story in full you will need to login or make a payment (see right).
MORE ARTICLES LIKE THIS
These links to content published by NPG are automatically generated.
RESEARCH
Crystal structure of turnip yellow mosaic virusNature Structural Biology Article (01 Sep 1996)
Anti-neutrophil cytoplasmic antibodies: Current diagnostic and pathophysiological potentialKidney International Original Article
Oxygen-17 NMR in solids by dynamic-angle spinning and double rotationNature Letters to Editor (04 May 1989)
See all 8 matches for Research
