Access

Letters to Nature

Nature 430, 806-810 (12 August 2004) | doi:10.1038/nature02735; Received 17 March 2004; Accepted 3 June 2004

Open Innovation Challenges

  • Single-cell Analysis Platform

    • Deadline: Dec 02 2009
    • Reward: $5,000 USD

    This Challenge is looking for novel approaches to analyzing changes at a single-cell level. This is...

  • Optimizing Sub-cellular Localization Tags

    • Deadline: Nov 29 2009
    • Reward: $20,000 USD

    The Seeker is looking for methods to optimize sub-cellular localization tags for protein expression....

naturejobs

Electron microscopic analysis of KvAP voltage-dependent K+ channels in an open conformation

Qiu-Xing Jiang1, Da-Neng Wang2 & Roderick MacKinnon1

  1. Howard Hughes Medical Institute and Laboratory of Molecular Neurobiology and Biophysics, Rockefeller University, 1230 York Avenue, New York, New York 10021,USA
  2. Skirball Institute of Biomolecular Medicine, New York University Medical Center, 540 First Avenue, New York, New York 10016,USA

Correspondence to: Roderick MacKinnon1 Email: mackinn@rockefeller.edu
The electron microscopy map has been deposited with European Bioinformatics Institute (http://www.ebi.ac.uk/msd/emd-2771.map).

Top

Voltage-dependent ion channels serve as field-effect transistors by opening a gate in response to membrane voltage changes1. The gate's response to voltage is mediated by voltage sensors2, which are arginine-containing structures that must move with respect to the membrane electric field. We have analysed by electron microscopy a voltage-dependent K+ channel from Aeropyrum pernix (KvAP)3. Fab fragments were attached to 'voltage sensor paddles' and identified in the electron microscopy map at 10.5 Å resolution. The extracellular surface location of the Fab fragments in the map is consistent with the membrane-depolarized, open conformation of the channel in electrophysiological experiments. Comparison of the map with a crystal structure4 demonstrates that the voltage sensor paddles are 'up' (that is, near the channel's extracellular surface) and situated at the protein–lipid interface. This finding supports the hypothesis that in response to changes in voltage the sensors move at the protein–lipid interface5 rather than in a gating pore surrounded by protein6, 7.

MORE ARTICLES LIKE THIS

These links to content published by NPG are automatically generated.

NEWS AND VIEWS

A glimpse at the grail

Nature Chemical Biology News and Views (01 Sep 2005)

Structural biology Life's transistors

Nature News and Views (01 May 2003)

See all 6 matches for News And Views