Access
To read this story in full you will need to login or make a payment (see right).
Letters to Nature
Nature 424, 751-754 (14 August 2003) | doi:10.1038/nature01841; Received 6 March 2003; Accepted 18 June 2003
Open Innovation Challenges
-
Protect Enzyme from In Planta Degradation
A proposal for stable expression of an enzyme in corn seed is desired.
-
Efficient Chromosome Doubling: Plant Cell Division
The Seeker is looking for an efficient chromosome doubling method in plants and in particular, metho...
nature jobs
Biochemist (Genetics / dna) Needed For Growing Nanostructure Designing Co. In Philadelphia
- KSR
- Blue Bell, PA, USA
Faculty positions
- The University of Alabama at Birmingham
- Birmingham, Alabama, USA
Erasable electrostatic lithography for quantum components
Rolf Crook1, Abi C. Graham1, Charles G. Smith1, Ian Farrer1, Harvey E. Beere1 & David A. Ritchie1
- Department of Physics, University of Cambridge, Madingley Road, Cambridge CB3 0HE, UK
Correspondence to: Charles G. Smith1 Email: cgs4@cam.ac.uk
Abstract
Quantum electronic components1, 2—such as quantum antidots and one-dimensional channels—are usually defined from doped GaAs/AlGaAs heterostructures using electron-beam lithography or local oxidation by conductive atomic force microscopy3, 4. In both cases, lithography and measurement are performed in very different environments, so fabrication and test cycles can take several weeks. Here we describe a different lithographic technique, which we call erasable electrostatic lithography (EEL), where patterns of charge are drawn on the device surface with a negatively biased scanning probe in the same low-temperature high-vacuum environment used for measurement. The charge patterns locally deplete electrons from a subsurface two-dimensional electron system (2DES) to define working quantum components. Charge patterns are erased locally with the scanning probe biased positive or globally by illuminating the device with red light. We demonstrate and investigate EEL by drawing and erasing quantum antidots, then develop the technique to draw and tune high-quality one-dimensional channels5, 6. The quantum components are imaged using scanned gate microscopy7, 8, 9, 10, 11. A technique similar to EEL has been reported previously, where tip-induced charging of the surface or donor layer was used to locally perturb a 2DES before charge accumulation imaging12.
- Department of Physics, University of Cambridge, Madingley Road, Cambridge CB3 0HE, UK
Correspondence to: Charles G. Smith1 Email: cgs4@cam.ac.uk
To read this story in full you will need to login or make a payment (see right).

