Original Article

Journal of Investigative Dermatology (1990) 95, 677–682; doi:10.1111/1523-1747.ep12514347

The Measurement of Skin Lymph Flow by Isotope Clearance—Reliability, Reproducibility, Injection Dynamics, and the Effect of Massage

Peter S Mortimer1, Rose Simmonds2, Mohi Rezvani2, Michael Robbins2, John W Hopewell2 and Terence J Ryan1

  1. 1Department of Dermatology, The Slade Hospital, Oxford, U.K.
  2. 2CRC Normal Tissue Radiobiology Group, The Research Institute, University of Oxford, Churchill Hospital, Oxford, U.K.

Received 8 March 1990; Accepted 2 August 1990.

Top

Abstract

The measurement of skin lymph flow was investigated using an isotope clearance technique (ICT). Multiple lymph flow determinations were undertaken in the skin of anaesthetized large white pigs to test for reproducibility, ascertain the most suitable tracer, study the influence of injection dynamics, and observe the effect of massage as a stimulus to lymph flow. Blood clearance of tracer was also investigated. Results demonstrated that lymphatic clearance is a mono-exponential function with good reproducibility under controlled laboratory conditions. 99mTc-colloid (TCK17 Cis) compared favorably with 131I-human serum albumin as a tracer and both performed better than colloid gold (198Au). Lymph flow was significantly faster in one pig than in the other. No difference existed between left and right sides or between caudal and rostral sites on each flank, but clearance was significantly slower in thigh than flank skin. Sub-epidermal injections cleared faster and more consistently than either deep or subcutaneous injections. Neither injection volume nor needle tract backflow of tracer influenced results, but local massage significantly enhanced clearance. Escape of 99Tc-colloid by the blood was negligible. These results indicate that skin lymph flow can be reliably measured when conditions are controlled. Extrinsic factors such as massage strongly influence lymph flow. Greater sensitivity in detecting degrees of lymphatic insufficiency may be achieved if a standardized stimulus to lymph flow is administered during isotope clearance measurement.

Top

References

  1. Engelhart, M, Kristensen, JK: Evaluation of cutaneous blood flow responses by 133-Xenon washout and a laser-Doppler flowmeter. J Invest Dermatol 1983 80: 12–15,  | Article | PubMed | ChemPort |
  2. Young, CM, Hopewell, JW: The evaluation of an isotope clearance technique in the dermis of pig skin: a correlation of functional and morphology parameters. Microvasc Res 1980 20: 182–194,  | Article | PubMed | ChemPort |
  3. Silberberg-Sinakin, I, Thorbecke, GJ: Contact hypersensitivity and the Langerhans cell. J Invest Dermatol 1980 75: 61–67,  | Article | PubMed | ChemPort |
  4. Drinker, CK, Field, ME: The protein content of mammalian lymph and the relation of lymph to tissue fluid. Am J Physiol 1931 97: 32–39,  | ChemPort |
  5. Taylor, GW, Kinmonth, JB, Rollinson, E, Rotblat, J: Lymphatic circulation studied with radioactive plasma protein. Br Med J 1957 1: 133–137,
  6. Hollander, W, Reilly, P, Burrows, BA: Lymphatic flow in human subjects as indicated by the disappearance of 131I-labeled albumin from the subcutaneous tissue. J Clin Invest 1961 40: 222–233,  | PubMed | ChemPort |
  7. Fernandez, MJ, Davies, WT, Owen, GM, Tyler, A: Lymphatic flow in humans as indicated by the clearance of 125I-labeled albumin from the subcutaneous tissue of the leg. J Surg Res 1983 35: 101–104,  | Article | PubMed | ChemPort |
  8. Ellis, JP, Marks, R, Perry, BJ: Lymphatic function: the disappearance rate of 131I albumin from the dermis. Br J Dermatol 1970 82: 593–599,  | PubMed | ChemPort |
  9. Staberg, B, Klemp, P, Aasted, M, Worm, AM, Lund, P: Lymphatic albumin clearance from psoriatic skin. J Am Acad Dermatol 1983 9: 857–861,  | PubMed | ChemPort |
  10. Montagna, W, Yun, JS: The skin of the domestic pig. J Invest Dermatol 1964 43: 11–26,
  11. Donovan, WE: Experimental models in skin flap research 1975, In: Grabb WC, Myers MB (eds.). Skin flaps, Little, Brown & Co., Boston, pp 11–20,
  12. Berry, RJ, Wiernik, G, Patterson, TJ: Skin tolerance to fractionated X-irradiation in the pig: how good a predictor is the N.S.D. formula? Br J Radiol 1974 47: 185–190,  | PubMed | ChemPort |
  13. Marquardt, DW: An algorithm for least-squared estimation of non-linear parameters. J Soc Ind Appl Math 1963 11: 431–441,  | Article | ISI |
  14. Baker, MR, Bader, DL, Hopewell, JW: An apparatus for testing of mechanical properties of skin in vivo: its application to the assessment of normal and irradiated pig skin. Bioeng Skin 1988 4: 87–103,
  15. Holloway, GA: Cutaneous blood flow responses to injection trauma measured by laser doppler flowmetry. J Invest Dermatol 1980 74: 1–4,  | PubMed |
  16. Rayman, G, Williams, SA, Spencer, PD, Smaje, LH, Wise, PH, Tooke, JE: Impaired microvascular hyperaemic response to minor skin trauma in type I diabetes. Br Med J 1986 292: 1295–1298,  | ChemPort |
  17. Hudack, SS, McMaster, PD: Lymphatic participation in human cutaneous phenomena. J Exp Med 1933 57: 751–774,  | Article |
  18. Courtice, FC: Lymph and plasma proteins: barriers to their movement through the extracellular fluid. Lymphology 1971 4: 9–17,  | PubMed | ChemPort |
  19. Bollinger, A, Jager, K, Sgier, G, Seglias, J: Fluorescence Microlymphography. Circulation 1981 64: 1195–1200,  | PubMed | ChemPort |
  20. Mortimer, PS, Jones, RL, Ryan, T: Human skin lymphatics: Regional variation and relationship to elastin. In: Heim L (ed.). Immunology and Hematology Research: Progress in Lymphology 1984, 2: Immunology Research Foundations Inc., Newburgh, NY, pp 59–64,
  21. Szabo, G, Magyar, Z, Molnar, G: Lymphatic and venous transport of colloids from the tissue. Lymphology 1973 6: 69–79,  | PubMed | ChemPort |
  22. Sage, HM, Sinha, BK, Kizilay, D, Toulon, R: Radioactive colloidal gold measurements of lymph flow and functional patterns of lymphatics and lymph nodes in the extremities. J Nucl Med 1964 5: 6626–6642,
  23. Miller, GE, Smathers, JB, Seale, J, Hightower, D, Hood, D: Lymphatic clearance of radioactive sulphur colloid. Lymphology 1980 13: 24–29,  | PubMed | ChemPort |
  24. Pecking, A, Cluzan, R, Desprez-Curely, JP, Gucrin, P: Functional study of the limb lymphatic system. Phlebology 1986 1: 129–133,
  25. Miller, GE, Seale, JL: The mechanics of terminal lymph flow. J Biomech Eng 1985 107: 376–380,  | PubMed | ChemPort |
  26. Yoffey, JM, Courtice, FG: Lymphatics, Lymph and Lymphomyeloid Complex 1970 Academic Press, New York,
  27. Hall, JG, Morris, B, Woolley, G: Intrinsic rhythmic propulsion of lymph in unanesthetized sheep. J Physiol 1965 180: 336–349,  | PubMed | ChemPort |
  28. Calnan, JS, Pflug, JJ, Reis, ND, Taylor, LM: Lymphatic pressures and the flow of lymph. Br J Plast Surg 1970 23: 305–317,  | Article | PubMed | ChemPort |
  29. Olszewski, WL: Peripheral lymph: formation and immune function 1985 CRC Press Inc., Florida,
  30. Jacobsson, S: Lymph flow from the lower leg in man. Acta Chir Scand 1967 133: 79–81,  | PubMed | ChemPort |
  31. Parson, RJ, McMaster, PD: The effect of the pulse upon the formation and flow of lymph. J Exp Med 1938 68: 353–376,

Extra navigation

.
ADVERTISEMENT