Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Original Article
  • Published:

Validation of TONOPORT V blood-pressure measuring monitor in adults

Abstract

A new automatic blood-pressure (BP) measuring device TONOPORT V was evaluated according to the International Protocol for Validation of Blood Pressure Measuring Devices in adults by the European Society of Hypertension. BP values measured by the TONOPORT V were compared to BP readings from two independent observers. A total of 33 patients (20 males, 13 females) provided systolic and diastolic BP readings in the normotensive, borderline hypertensive, and hypertensive range. Their age varied between 30 and 83 years, and their arm circumference between 23 and 36 cm. The device showed a mean (±s.d.) deviation from observer measurements of −0.7 (4.6) mmHg for systolic and −0.8 (4.4) mmHg for diastolic BP. The accuracy of the device did not vary according to BP values or other patient characteristics. The device passed all phases of the protocol and can be recommended following the regulation rules of the European Society of Hypertension.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Figure 1
Figure 2

Similar content being viewed by others

References

  1. Mancia G, Parati G . Office compared with ambulatory blood pressure in assessing response to antihypertensive treatment: a meta-analysis. J Hypertens 2004; 22: 435–445.

    Article  CAS  Google Scholar 

  2. O'Brien E et al. on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring Blood pressure measuring devices: validated instruments. BMJ 2001; 322: 531–536.

    Article  CAS  Google Scholar 

  3. O'Brien E et al. The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 1990; 8: 607–619.

    Article  CAS  Google Scholar 

  4. O'Brien E et al. The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11 (Suppl 2): S43–S63.

    Google Scholar 

  5. O'Brien E et al. with the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7: 3–17.

    Article  Google Scholar 

  6. O'Brien E, Atkins N, Murphy A, Lyons S . Validation of the TONOPORT V ambulatory blood pressure monitor according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring Devices in Adults. Blood Press Monit 2003; 8: 255–260.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to W Langewitz.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Haensel, A., Utech, K. & Langewitz, W. Validation of TONOPORT V blood-pressure measuring monitor in adults. J Hum Hypertens 19, 745–749 (2005). https://doi.org/10.1038/sj.jhh.1001876

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.jhh.1001876

Keywords

This article is cited by

Search

Quick links