Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Original Article
  • Published:

Treating hypertension with a device that slows and regularises breathing: a randomised, double-blind controlled study

Abstract

Objective: To examine the efficacy of a new device, which slows and regularises breathing, as a non-pharmacological treatment of hypertension and thus to evaluate the contribution of breathing modulation in the blood pressure (BP) reduction.

Design and setting: Randomised, double-blind controlled study, carried out in three urban family practice clinics in Israel.

Patients: Sixty-five male and female hypertensives, either receiving antihypertensive drug therapy or unmedicated. Four patients dropped out at the beginning of the study.

Intervention: Self treatment at home, 10 minutes daily for 8 consecutive weeks, using either the device (n = 32), which guides the user towards slow and regular breathing using musical sound patterns, or a Walkman, with which patients listened to quiet music (n = 29). Medication was unchanged 2 months prior to and during the study period.

Main outcome measures: Systolic BP, diastolic BP and mean arterial pressure (MAP) changes from baseline.

Results: BP reduction in the device group was significantly greater than a predetermined ‘clinically meaningful threshold’ of 10.0, 5.0 and 6.7 mm Hg for the systolic BP, diastolic BP and MAP respectively (P = 0.035, P = 0.0002 and P = 0.001). Treatment with the device reduced systolic BP, diastolic BP and MAP by 15.2, 10.0 and 11.7 mm Hg respectively, as compared to 11.3, 5.6 and 7.5 mm Hg (P = 0.14, P = 0.008, P = 0.03) with the Walkman. Six months after treatment had stopped, diastolic BP reduction in the device group remained greater than the ‘threshold’ (P < 0.02) and also greater than in the walkman group (P = 0.001).

Conclusions: The device was found to be efficacious in reducing high BP during 2 months of self-treatment by patients at home. Breathing pattern modification appears to be an important component in this reduction.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to MH Schein.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schein, M., Gavish, B., Herz, M. et al. Treating hypertension with a device that slows and regularises breathing: a randomised, double-blind controlled study. J Hum Hypertens 15, 271–278 (2001). https://doi.org/10.1038/sj.jhh.1001148

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date: