This study assessed differences in the indoor air quality and occupancy levels in seventeen bars due to a city-wide smoking ban that took effect on September 1, 2005 in Austin, Texas, USA. We measured the following in each venue before and after the smoking ban: mean number of occupants, mean number of lit cigarettes, temperature, relative humidity, room volume, and PM2.5, CO, and CO2 concentrations. Additionally, VOC measurements were conducted at three of the venues. There was not a statistically significant change in occupancy, but the best estimate PM2.5 concentrations in the venues decreased 71–99%, a significant reduction in all venues, relative to the pre-ban levels; CO concentrations decreased significantly in all but one venue; and concentrations of VOCs known to be emitted from cigarettes decreased to below the detection limit for all but two common compounds. These results suggest that the smoking ban has effectively improved indoor air quality in Austin bars without an associated decrease in occupancy.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 6 print issues and online access
$259.00 per year
only $43.17 per issue
Rent or buy this article
Prices vary by article type
from$1.95
to$39.95
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Akbar-Khanzadeh F. Exposure to environmental tobacco smoke in restaurants without separate ventilation systems for smoking and nonsmoking dining areas. Arch Env Health 2003: 58(2): 97–103.
Austin Health and Human Services department. 2006 Accessed on 1/2/06. http://www.ci.austin.tx.us/health/ech_smokingord.htm.
Baek S.O., and Jenkins R.A. Characterization of trace organic compounds associated with aged and diluted sidestream tobacco smoke in a controlled atmosphere — volatile organic compounds and polycyclic aromatic hydrocarbons. Atmos Env 2004: 38(38): 6583–6599.
Bates M.N., Fawcett J., Dickson S., Berezowski R., and Garrett N. Exposure of hospitality workers to environmental tobacco smoke. Tobacco Control 2002: 11(2): 125–129.
Branis M., Rezacova P., and Guignon N. Fine particles (PM1) in four different indoor environments. Indoor Built Env 2002: 11(4): 184–190.
Carrington J., Watson A.F.R., and Gee I.L. The effects of smoking status and ventilation on environmental tobacco smoke concentrations in public areas of UK pubs and bars. Atmos Env 2003: 37(23): 3255–3266.
Dingle P., Tapsell P., Tremains I., and Tan R. Environmental tobacco smoke and ventilation in 20 social venues in Perth, Western Australia. Indoor Built Env 2002: 11(3): 146–152.
Hopkins D.P., Briss P.A., Ricard C.J., Husten C.G., Carande-Rulis V.G., Fielding J.E., Alao M.O., McKenna J.W., Sharp D.J., Harris J.R., Woollery T.A., and Harris K.W. Reviews of evidence regarding interventions to reduce tobacco use and exposure to environmental tobacco smoke. Am J Prevent Med 2001: 20(2): 67–87.
Jenkins R.A., and Counts R.W. Occupational exposure to environmental tobacco smoke: results of two personal exposure studies. Env Health Perspect 1999: 107: 341–348.
Jenkins R.A., Ilgner R.H., Tomkins B.A., and Peters D.W. Development and application of protocols for the determination of response of real-time particle monitors to common indoor aerosols. J Air Waste Manage Assoc 2004: 54(2): 229–241.
Johnsson T., Tuomi T., Hyvarinen M., Svinhufvud J., Rothberg M., and Reijula K. Occupational exposure of non-smoking restaurant personnel to environmental tobacco smoke in Finland. Am J Ind Med 2003: 43(5): 523–531.
Klepis N.E., Apte M.G., Gundel L.A., Sextro R.G., and Nazaroff W.W. Determining Size-Specific Emission Factors for Environmental Tobacco Smoke Particles. Aerosol Sci Technol 2003: 37: 780–790.
Kolokotroni M., Perera M.D.A.E.S., Palmer J., Currie J., Capper G., and Watkins R. Effectiveness of simple ventilation strategies and partitioning in mitigating the effects of passive smoking. Building Services Eng Res Technol 1999: 20(2): 93–98.
Lindgren T., Willers S., Skarping G., and Norback D. Urinary cotinine concentration in flight attendants, in relation to exposure to environmental tobacco smoke during intercontinental flights. Int Arch Occup Env Health 1999: 72(7): 475–479.
Maskarinec M.P., Jenkins R.A., Counts R.W., and Dindal A.B. Determination of exposure to environmental tobacco smoke in restaurant and tavern workers in one US city. J Exposure Anal Env Epidemiol 2000: 10(1): 36–49.
Meyer B. Indoor Air Quality. Addison-Wesley Publishing Company, Inc., Reading, MA, 1983.
Mulcahy M., Byrne M.A., and Ruprecht A. How does the Irish smoking ban measure up? A before and after study of particle conentrations in Irish pubs. Proceedings of Indoor Air 2005, Beijing, China, 2005, pp. 1659–1662.
National Cancer Institute. Smoking and Tobacco Control Monograph 10: Health Effects of Exposure to Environmental Tobacco Smoke. National Cancer Institute, Rockville, MD, 1999.
National Research Council. Environmental Tobacco Smoke—Measuring Exposures and Assessing Health Effects. National Academy Press, Washington, DC, 1986.
NIOSH Current Intelligence Bulletin #54. Environmental Tobacco Smoke in the Workplace, Lung Cancer and Other Health Effects. U.S. Department of Health and Human Services, National Institute for Occupational Safety and Health, Cincinnati, OH, 1991.
Ott W., Switzer P., and Robinson J. Particle concentrations inside a tavern before and after prohibition of smoking: evaluating the performance of an indoor air quality model. J Air Waste Manage 1996: 46: 1120–1134.
Repace J. Respirable particles and carcinogens in the air of Delaware hospitality venues before and after a smoking ban. J Occup Env Med 2004: 46(9): 887–905.
Repace J.L., and Lowrey A.H. Indoor air-pollution, tobacco-smoke, and public-health. Science 1980: 208(4443): 464–472.
Sargent R.P., Shepard R.M., and Glantz S.A. Reduced incidence of admissions for myocardial infarction associated with public smoking ban: before and after study. Br Med J 2004: 328(7446): 977–980.
Surgeon General. The Health Consequences of Involuntary Smoking, A Report of the Surgeon General. U.S. Department of Health and Human Services, Washington, DC, 1986.
Trout D., Decker J., Mueller C., Bernert J.T., and Pirkle J. Exposure of casino employees to environmental tobacco smoke. J Occup Env Med 1998: 40(3): 270–276.
U.S. Environmental Protection Agency. Respiratory Health Effects of Passive Smoking (Also Known as Exposure to Secondhand Smoke or Environmental Tobacco Smoke ETS). U.S. EPA, Office of Research and Development, Office of Health and Environmental Assessment, Washington, DC, 1992.
U.S. Environmental Protection Agency. Exposure Factors Handbook Vol. 1—General Factors. U.S. EPA. U.S. Government Printing Office, Washington, DC, 1997.
Acknowledgements
The American Cancer Society provided funding for this research. Phil Huang and the staff at the Texas Department of State Health Services (TDSHS) collaborated on this study, acted as the second field team, and conducted the VOC sample analyses.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Waring, M., Siegel, J. An evaluation of the indoor air quality in bars before and after a smoking ban in Austin, Texas. J Expo Sci Environ Epidemiol 17, 260–268 (2007). https://doi.org/10.1038/sj.jes.7500513
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jes.7500513
Keywords
This article is cited by
-
Experimental and computational study of particulate matter of secondhand smoke in indoor environment
International Journal of Environmental Science and Technology (2015)
-
Measurement of fine particles and smoking activity in a statewide survey of 36 California Indian casinos
Journal of Exposure Science & Environmental Epidemiology (2011)
-
Monitoring of long-term personal exposure to fine particulate matter (PM2.5)
Air Quality, Atmosphere & Health (2010)
-
Are there health benefits associated with comprehensive smoke-free laws
International Journal of Public Health (2009)