Original Article

Journal of Cerebral Blood Flow & Metabolism (2006) 26, 1431–1441. doi:10.1038/sj.jcbfm.9600289; published online 1 March 2006

Evaluation of reference tissue models for the analysis of [11C](R)-PK11195 studies

This research was supported by a grant from the Dutch Brain Foundation provided to BNM van Berckel.

Marc A Kropholler1, Ronald Boellaard1, Alie Schuitemaker1,2, Hedy Folkersma3, Bart N M van Berckel1 and Adriaan A Lammertsma1

  1. 1Department of Nuclear Medicine & PET Research, VU University Medical Center, Amsterdam, The Netherlands
  2. 2Department of Neurology, VU University Medical Center, Amsterdam, The Netherlands
  3. 3Department of Neurosurgery, VU University Medical Center, Amsterdam, The Netherlands

Correspondence: MA Kropholler, Department of Nuclear Medicine & PET Research, VU University Medical Center, PO Box 7057, 1007 MB Amsterdam, The Netherlands. E-mail: ma.kropholler@vumc.nl

Received 13 October 2005; Revised 30 November 2005; Accepted 23 January 2006; Published online 1 March 2006.

Top

Abstract

[11C](R)-PK11195 is a marker of activated microglia, which can be used to measure inflammation in neurologic disorders. The purpose of the present study was to define the optimal reference tissue model based on a comparison with a validated plasma input model and using clinical studies and Monte Carlo simulations. Accuracy and reproducibility of reference tissue models were evaluated using Monte Carlo simulations. The effects of noise and variation in specific binding, nonspecific binding and blood volume were evaluated. Dynamic positron emission tomography scans were performed on 13 subjects, and radioactivity in arterial blood was monitored online. In addition, blood samples were taken to generate a metabolite corrected plasma input function. Both a (validated) two-tissue reversible compartment model with K1/k2 fixed to whole cortex and various reference tissue models were fitted to the data. Finally, a simplified reference tissue model (SRTM) corrected for nonspecific binding using plasma input data (SRTMpl_corr) was investigated. Correlations between reference tissue models (including SRTMpl_corr) and the plasma input model were calculated. Monte Carlo simulations indicated that low-specific binding results in decreased accuracy and reproducibility. In this respect, the SRTM and SRTMpl_corr performed relatively well. Varying blood volume had no effect on performance. In the clinical evaluation, SRTMpl_corr and SRTM had the highest correlations with the plasma input model (R2=0.82 and 0.78, respectively). SRTMpl_corr is optimal when an arterial plasma input curve is available. Simplified reference tissue model is the best alternative when no plasma input is available.

Keywords:

microglia, peripheral benzodiazepine receptor, PET (positron emission tomography), PK11195, reference tissue models, tracer kinetic modelling

MORE ARTICLES LIKE THIS

These links to content published by NPG are automatically generated.

Extra navigation

.

naturejobs

ADVERTISEMENT