Nature Publishing Group, publisher of Nature, and other science journals and reference works NATURE.COM NATURE NEWS NATUREJOBS NATUREEVENTS ABOUT NPG
Help Nature.com site index  
International Journal of Obesity
SEARCH     advanced search my account e-alerts subscribe register
Journal home
Advance online publication
Current issue
Archive
Press releases
For authors
For referees
Contact editorial office
About the journal
For librarians
Subscribe
Advertising
naturereprints
Contact NPG
Customer services
Site features
NPG Subject areas
Access material from all our publications in your subject area:
Biotechnology Biotechnology
Cancer Cancer
Chemistry Chemistry
Dentistry Dentistry
Development Development
Drug Discovery Drug Discovery
Earth Sciences Earth Sciences
Evolution & Ecology Evolution & Ecology
Genetics Genetics
Immunology Immunology
Materials Materials Science
Medical Research Medical Research
Microbiology Microbiology
Molecular Cell Biology Molecular Cell Biology
Neuroscience Neuroscience
Pharmacology Pharmacology
Physics Physics
Browse all publications
 
April 2001, Volume 25, Number 4, Pages 486-490
Table of contents    Previous  Abstract  Next   Full text  PDF
Paper
Continuous negative abdominal pressure device to treat pseudotumor cerebri
H J Sugerman1, W L Felton III2, A Sismanis3, B H Saggi1, J M Doty1, C Blocher1, A Marmarou1 and R G Makhoul1

1Department of Surgery, Medical College of Virginia of Virginia Commonwealth University, Richmond, Virginia, USA

2Department of Neurology and Ophthalmology, Medical College of Virginia of Virginia Commonwealth University, Richmond, Virginia, USA

3Department of Oral Maxillofacial Surgery, Medical College of Virginia of Virginia Commonwealth University, Richmond, Virginia, USA

Correspondence to: H J Sugerman, Box 980519, Richmond, VA 23298-0519, USA. E-mail: hsugerma@hsc.vcu.edu

Abstract

OBJECTIVE: To study the effects of an externally applied negative abdominal pressure device designed to lower the effects of intra-abdominal pressure (IAP) on headaches and pulsatile tinnitus in severely obese women with pseudotumor cerebri (PTC).

DESIGN: Short-term clinical intervention trial in the Clinical Research Center. Days 1 and 3 were 'control' days; on days 2 and 4-6 patients were in the device from 8:00 am to noon and from 1:00 to 5:00 pm, and on nights 7-11 they were in the device from 10:00 pm to 8:00 am. The last four patients were treated in a device with a counter-traction mechanism.

SUBJECTS: Seven centrally obese women with PTC.

MEASUREMENTS: Headache and pulsatile tinnitus severity were graded by the patient using visual analog scale (1-10) and averaged for the time that the device was in use or not in use. IAP was estimated from urinary bladder pressure (UBP) before and during device use. The internal jugular vein (IJV) elliptical cross-sectional area was measured with B-mode ultrasonography; the timed average velocity was measured by Doppler.

RESULTS: There was a decrease in both headache (6.8±0.8 to 4.2±0.8, P<0.05) and pulsatile tinnitus (4.2±0.5 to 1.8±0.5, P<0.02) within 5 min, and in headache (to 2.2±0.8, P<0.01) and tinnitus (to 1.7±0.5, P<0.01) within 1 h of device activation. UBP decreased (P<0.001) from 19.1±3 to 12.5±2.8 cmH2O. Headache remained improved throughout time that the device was used. During the second week, five of seven patients slept in the device without difficulty and four awoke without headache. There was a progressive decrease (P<0.01) in headache during the day after sleeping in the device at night as compared with days 1 and 3 when it was not used (6.5±0.5, day 1; 4.1±0.7, day 3; 3.1±0.8, day 8; 2.3±0.8, day 10). Headaches returned late in the afternoon in two patients; the device was reactivated and headache again improved. Five patients underwent IJV sonography; the IJV area decreased (129±53 to 100±44 mm2, P=0.06) without a change in IJV flow (1004±802 to 1000±589 ml/min) with the device. When activated, the device was pulled into the patient, creating discomfort that was alleviated with the counter-traction mechanism in the last four patients. One patient developed a 5 cm area of blisters that resolved when the device was worn over a hospital gown.

CONCLUSIONS: Decreasing IAP relieved headaches and pulsatile tinnitus in PTC. When patients slept in the device, they awoke without headache or tinnitus, which remained markedly improved throughout most of the following day. This study supports the hypothesis that PTC in obese women is secondary to an increased IAP.

International Journal of Obesity (2001) 25, 486-490

Keywords

abdominal pressure; negative pressure device; pulsatile tinnitus; headache

Received 22 February 2000; revised 19 October 2000; accepted 30 October 2000
April 2001, Volume 25, Number 4, Pages 486-490
Table of contents    Previous  Abstract  Next   Full text  PDF