Abstract
Hypoxia has been associated with poor local tumour control and relapse in many cancer sites, including carcinoma of the prostate. This translational study tests whether breathing carbogen gas improves the oxygenation of human prostate carcinoma xenografts in mice and in human patients with prostate cancer. A total of 23 DU145 tumour-bearing mice, 17 PC3 tumour-bearing mice and 17 human patients with prostate cancer were investigated. Intrinsic susceptibility-weighted MRI was performed before and during a period of carbogen gas breathing. Quantitative R2* pixel maps were produced for each tumour and at each time point and changes in R2* induced by carbogen were determined. There was a mean reduction in R2* of 6.4% (P=0.003) for DU145 xenografts and 5.8% (P=0.007) for PC3 xenografts. In all, 14 human subjects were evaluable; 64% had reductions in tumour R2* during carbogen inhalation with a mean reduction of 21.6% (P=0.0005). Decreases in prostate tumour R2* in both animal models and human patients as a result of carbogen inhalation suggests the presence of significant hypoxia. The finding that carbogen gas breathing improves prostate tumour oxygenation provides a rationale for testing the radiosensitising effects of combining carbogen gas breathing with radiotherapy in prostate cancer patients.
Similar content being viewed by others
Main
The relationship of radiosensitivity to varying oxygenation and the detrimental effects of hypoxia in human tumours was first shown over 50 years ago (Gray et al, 1953; Tomlinson and Gray, 1955). Since then, it has been established that hypoxia is an important factor in radiotherapy treatment failure and has been associated in clinical studies with poor local tumour control and relapse in many cancer sites (Nordsmark et al, 1996; Fyles et al, 1998; Brizel et al, 1999; Movsas et al, 2002; Hoskin et al, 2003).
Eppendorf microelectrode measurements have been used to invasively characterise the range and heterogeneity of oxygen partial pressures in the prostate and show that hypoxic regions exist in human prostate carcinoma (Movsas et al, 1999; Parker et al, 2004). The outcome of radical radiotherapy for prostate cancer is influenced by the presence of hypoxia. A study that prospectively analysed 57 patients with localised disease showed that hypoxic tumours had a significantly worse biochemical relapse-free survival at 2 years (31 vs 92%, P<0.0001; Movsas et al, 2002). Oxygenation status is therefore an additional prognostic factor beyond the classic prognostic factors (age, clinical stage, Gleason score and prostate-specific antigen) that predicts radiation treatment failure in prostate cancer. A modelling study based on these clinical data predicts an oxygen enhancement ratio for prostate cancer of 1.4 (95% confidence interval of 1.2–1.8) that is consistent with the in vitro OER measurements of human tumour cell lines under chronic hypoxia conditions (Wang et al, 2006). These data taken together suggest that hypoxia is likely to be a valid therapeutic target in prostate cancer.
The rationale for using a high oxygen-content gas to improve tumour oxygenation is that the resulting increase in arterial pO2 will enhance the diffusion of soluble oxygen into tissues. Carbogen is a normobaric high oxygen content gas mixture, which is usually administered at one of the two concentrations (95% O2 with 5% CO2 or 98% O2 with 2% CO2). Carbogen has been shown to improve the oxygenation of both experimental and human tumours (Falk et al, 1992; Robinson et al, 1997; Powell et al, 1999; Rijpkema et al, 2002). This gas mixture increases intravascular oxygen availability resulting in greater oxygen uptake by tumours. It also transiently increases tumour blood flow (possibly due to a vasodilatory effect mediated by CO2), which increases oxygen delivery to regions of perfusion-limited hypoxia (Sibtain et al, 2002). Extracellular tumour pH has been shown to decline in response to carbogen gas breathing, particularly for large and hypoxic tumours (McSheehy et al, 1998). A study in a murine tumour model showed that the level of radiosensitisation achieved is dependent on both the CO2 content of the inspired gas and the duration of gas breathing (Hill et al, 1998).
Hypoxia modification has been shown to improve radiotherapy outcomes in several tumour sites, including the use of carbogen gas breathing in combination with hypofractionated, conventional and hyperfractionated radiotherapy schedules (Overgaard and Horsman, 1996). Despite this, there has been a paucity of investigation into its value in prostate cancer. In this study, blood oxygen level-dependent (BOLD) MRI, also called intrinsic susceptibility MRI, has been used to show the changes in blood oxygenation in response to carbogen inhalation in two animal models and in human subjects. This imaging technique capitalises on the differing magnetic properties of oxygenated and deoxygenated blood. Deoxyhaemoglobin is paramagnetic and acts as an intravascular contrast agent because it brings about an increase in the transverse relaxation rates of blood and surrounding tissues. Microscopic field gradients in the vicinity of red blood cells and vessels are modulated by the changes in the deoxyhaemoglobin concentration, which leads to signal attenuation in susceptibility-weighted MR images (Alonzi and Hoskin, 2006). Thus, the purpose of this study was to evaluate changes in prostate tumour oxygenation using BOLD MRI in response to carbogen breathing.
Materials and methods
Animal experiments
All animal experiments were performed in full compliance with UK government regulations and local guidelines on animal welfare and were approved by the local ethical review committee.
Cell culture and implant
DU145 and PC3 cells were incubated under 19.6% O2, 5% CO2 and 75.4% N2 at 37°C. Both cell lines were originally isolated from patients with metastatic hormone refractory prostate cancer (Mickey et al, 1977; Stone et al, 1978; Kaighn et al, 1979). The cells were maintained in Dulbecco's Modified Eagle Media (DMEM) supplemented with 10% foetal calf serum (FCS), 2 mM L-glutamine, 100 U ml−1 penicillin and 100 μg ml−1 streptomycin. Tumours were initiated by injecting (2 × 106 cells) subcutaneously into the rear dorsum of 8–10-week-old SCID mice. Animals were selected for investigation when their tumours reached 8–10 mm geometric mean diameter.
Imaging for tumour hypoxia
Mice were sedated for each MRI scan using 200 μl of 1 : 10 hypnorm in water, injected into the peritoneal cavity. Sedated mice were placed in a 6-cm diameter quadrature birdcage coil (Varian, Palo Alto, CA, USA) in a 4.7 tesla Varian MR system. A hot air blower with continuous temperature monitoring was used to maintain body temperature.
Initial T1-weighted sagittal and transverse scans were obtained for localisation. Multiple spoiled gradient echo (GRE) images were acquired on a single central slice with increasing echo times (TE=4–48 ms, in 4 ms steps), with TR 117 ms, flip angle (α) 45°, slice thickness 1 mm, and field of view 40 × 45 mm. Scanning time was divided into three gas-breathing periods with mice breathing air, carbogen (95% O2 and 5% CO2) and then air again. The first air breathing period lasted 4 min, followed by 10 min of carbogen breathing and then 4 min breathing air. Images were obtained every minute, resulting in 18 images for each xenograft. All gases were administered at 1 l min−1 (gases obtained from BOC, UK). A vacuum-based gas scavenger was used to minimise changes in oxygen content within the magnet bore. GRE images with the same imaging parameters that were used for the baseline scan were acquired every minute throughout the experiment.
Animal MR image analysis
Multiecho sequence images were processed using Matlab version 5 (Mathworks, Nantick, MA, USA). A region of interest (ROI) was drawn around the tumour using the initial T1-weighted image. R2* pixel maps were then calculated for each time point of the imaging series. For each pixel, a straight line was fitted to a plot of lnSt against TE for each pixel using a least-squares approach, of which the gradient is intrinsic relaxivity (−R2*; s−1).
Statistical analysis
Repeatability was assessed by comparing two of the baseline BOLD sequences taken 1 min apart during the air-breathing period at the beginning of the carbogen experiment (time points two and three) for each xenograft. Bland and Altman (1996a, 1996b, 1996c) statistics for measuring repeatability were used. This gave a range, based on the repeatability of the entire group, of the change required in any given xenograft to be considered statistically significant at the 95% confidence level and not simply be due to the natural test variability. The effect of hyperoxia on R2* was evaluated using the time series of repeated BOLD MRI scans during carbogen breathing. The first four baseline R2* measurements, before the carbogen gas exposure was initiated, were averaged to give a single baseline value. The remaining R2* values (measurements 5–18) were subtracted from the baseline measurement to give a ΔR2* value, that is, the change in R2* from baseline. Group significance testing was performed using the paired two-tailed student's t-test. Correlation between baseline R2* and ΔR2* was assessed using Pearson's correlation coefficient.
Human testing
A total of 17 patients with prostate cancer (age=56–76 years, Gleason grade=6–8, PSA=1.9–32.0 ng ml−1) that were due to be treated with a radical prostatectomy procedure were recruited. None had received hormonal treatment. Investigations were performed after approval by a local institutional review board and full ethics committee approval. Written informed consent was obtained from each subject. The histological diagnosis of prostate cancer was made by core biopsy in all patients. Patients were imaged in a Symphony 1.5T MRI scanner (Siemens Medical Systems, Erlangen, Germany) using phased array pelvic coils.
Imaging for tumour hypoxia
The small field-of-view images of T2-weighted anatomical scans perpendicular to the urethra were used to stage tumours and to identify tumour slice locations. Images were inspected for the presence of a peripheral zone abnormality consistent with cancer. An oncological radiologist inspected the images, and the slice location for BOLD imaging was chosen.
For each patient, five spoiled gradient-echo images were acquired for three slices through the prostate with varying TE (5–60 ms), TR=100 ms, flip angle=40°, FOV=200 mm, 2562 matrix, and 8 mm thickness from which R2* maps were calculated. Imaging was performed at three time points: (1) initial BOLD MRI (breathing room air) to determine baseline R2* values, (2) second BOLD MRI (breathing room air) performed immediately after the first BOLD scan to establish the repeatability of the BOLD technique, (3) third BOLD scan initiated after 10 min of carbogen breathing. Carbogen was administered through a tight-fitting facemask and continued for the duration of the BOLD acquisition. A 98% O2 and 2% CO2 mixture was used to maximise patient compliance (Powell et al, 1999).
MRI data analysis
Tumour ROIs were outlined using the T2-weighted anatomical scans. In general, an irregular mass of low signal intensity seen on the T2-weighted images was considered to represent tumour. When an obvious malignant peripheral zone tumour was contiguous with homogeneous low signal intensity in the central gland, the ROI of interest was expanded to encompass the entire visible abnormality. A consultant radiologist with a specialist interest in prostate cancer imaging independently verified these regions (ARP).
Voxel-based calculations were performed using DiffusionView© version 2.1.3, a customised analysis software package developed in IDL (Research Systems; Boulder, CO, USA) at the Institute of Cancer Research, London, UK. R2* maps were created by pixel-by-pixel fitting of a straight line to a plot of lnSt against TE for each pixel using a least-squares approach, of which the gradient is −R2* (s−1). Pixels with either negative or zero values were excluded from the analysis.
Statistical analysis
The same statistical analysis as the animal study was used for the human experiments, the only differences being that two rather than four baseline (air-breathing) time points were available from which to calculate the baseline R2* measurement and only a single carbogen-breathing image was obtained.
Results
Animal experiments
A total of 23 DU145 tumour-bearing mice and 17 PC3 tumour-bearing mice were investigated. Baseline R2* values for the two xenograft models overlapped and both showed marked heterogeneity ranging from 15.4 to 135.0 s−1 (Figure 1). The test proved to be extremely repeatable with a coefficient of variation (wCV) of 3.4% for DU145 tumours and 2.2% for PC3 tumours. For an individual xenograft, a reduction in R2* of 9.3% for DU145 tumours and 6.3% for PC3 tumours could be considered significant at the 95% confidence level (i.e. not simply a result of test variability). Analysis on an individual tumour by tumour basis for DU145 and PC3 tumours showed that four (17.4%) of the DU145 tumour-bearing mice and five (29.4%) of the PC3 tumour-bearing mice had reductions in R2* that could be considered statistically significant at the 95% confidence level (Figure 1). Analysis of the two groups as a whole showed a mean reduction in R2* of 3.52 s−1 or 6.4% (P=0.003) for the DU145 tumours and 3.04 s−1 or 5.8% (P=0.007) for the PC3 tumours.
The carbogen time series graphs show the temporal effect of carbogen breathing on the oxygenation of the prostate cancer xenografts (Figure 2). R2* values fall rapidly after the commencement of carbogen breathing as tumour oxygen levels increase. By the end of the experiment, the R2* values have essentially returned to baseline. Interestingly, in both DU145 and PC3 tumours, R2* values seem to begin a return towards their baseline reading before the carbogen exposure had been terminated. For DU145 tumours, this occurs after approximately 9 min and with PC3 tumours, the effect is seen earlier, at about 4–5 min. Following the cessation of carbogen breathing, R2* values for the DU145 xenografts seemed to ‘overshoot’, finishing at a higher level than at baseline. However, this difference was not statistically significant.
There was no correlation between the baseline R2* value and the change in R2* following carbogen exposure, for either tumour type.
Human testing
All 17 patients completed the two baseline BOLD scans. One patient was unable to tolerate carbogen breathing, due to a feeling of claustrophobia while in the MRI scanner wearing a facemask. In two other patients, it was not possible to locate tumour on the imaging slices. This left 14 patients available for analysis.
Baseline R2* values for the human tumours were lower than those found in the xenografts because of the magnetic field strength dependence of R2* relaxivities (Blockley et al, 2008), and also showed less heterogeneity (R2*=7.1–29.2 s−1). The susceptibility-weighted BOLD technique proved to be highly repeatable in human prostate cancer with a wCV of 4.7%. For an individual patient's prostate tumour, a change in R2* of 1.95 s−1 (or 12.9%) could be considered significant at the 95% confidence level. Analysis of tumour regions on an individual patient-by-patient basis showed that 9 of the 14 patients (64%) had reductions in tumour R2* during carbogen exposure that could be considered statistically significant at the 95% confidence level (Figure 3). Analysis of the group as a whole showed a mean reduction in R2* of 3.52 s−1 or 21.6% (P=0.0005) for the prostate tumour ROIs.
As for the xenografts, there was no correlation between the baseline R2* value and the change in R2* following carbogen exposure.
Discussion
This study is the first to have quantified the BOLD effect with the calculation of R2* values in both prostate cancer xenografts and human tumours (these results are remarkably concordant). Using repeatability statistics, we were also able to confidently identify, on an individual basis, whether or not there is an oxygen-enhancing effect of carbogen breathing for every tumour. Two-thirds of the prostate cancer patients had a statistically significant reduction in R2* following carbogen exposure. These results expand on a previous demonstration of an oxygen-enhancing effect of carbogen breathing in the benign human prostate gland (Taylor et al, 2001).
The two xenografts used in this study are known to be hypoxic, with median pO2 values shown to be 3.0–6.4 mm Hg when investigated in a study using the Eppendorf histograph (Teicher et al, 1994). The same report also described the heterogeneity of oxygenation measurements between xenografts that is corroborated by the wide variation in baseline R2* measurements seen in the current study. The reason why there is a greater variation in baseline oxygenation in the xenografts compared with human tumours is unclear. One explanation may be that the xenografts exhibited substantial and variable degrees of necrosis with a mean of 18.1% (range=0–74.9%) of the total cross-sectional PC3 tumour area being necrotic and a mean of 9.4% (range=0–35.7%) for DU145 tumours. In contrast, necrosis is not a major feature of human prostate cancer. Areas of necrosis would have a low R2* value because of the lack of viable red blood cell delivery. These regions are surrounded by an area of diffusion-limited hypoxia with a disorganised vascular network that results in a fluctuant, unpredictable blood supply, and these areas would be expected to have higher R2* values.
One may expect that the most hypoxic tumours should show the greatest benefit from carbogen exposure. This has not been shown for either xenograft or for the human tumours in this study, with no correlations seen between the baseline R2* value and the change in R2* following carbogen exposure. This lack of concordance has been reported in earlier studies of various tumour types, using both microelectrode and imaging methods for hypoxia detection (Teicher et al, 1994; Howe et al, 1999; Powell et al, 1999; Taylor et al, 2001). It would appear that it is not necessarily the most hypoxic tumours that exhibit the greatest response from carbogen breathing. However, as defined by R2*, tumours that demonstrate a clear response are hypoxic. Also, it seems that separate areas of equivalent hypoxia within a single tumour may not respond equally to carbogen stimulation. These findings reflect the complexity and heterogeneity of the microregional vascular and endocrine environment within tumours. As a result, it is only possible to use BOLD-MRI to measure the response to carbogen breathing, but not to predict which tumours are likely to respond to carbogen exposure.
The use of BOLD-MRI for assessment of tissue hypoxia is based on the assumption that oxygenation of haemoglobin is related to blood arterial pO2 (as described by the oxygen-haemoglobin dissociation curve), which is in equilibrium with oxygenation of surrounding tissues. Several studies have shown that R2* changes in response to vasomodulation with carbogen are temporally correlated with changes in tissue pO2 (Al-Hallaq et al, 1998; Robinson et al, 1999; Taylor et al, 2001). Tumours appear to differ in their ability to respond to carbogen inhalation with only 50–60% of human tumours showing changes in R2* (Taylor et al, 2001). The reasons for even hypoxic tumours having limited and heterogeneous responses are complex, but undoubtedly include the fact that tumours may have adapted to widely different perfusion environments. It is to be noted that even when vessels are present, red blood cell transport through these vessels may not be effective (Robinson et al, 2003). Thus, hypoxic tumours with high blood volume (due to high microvessel density coupled with large vessels) will have raised baseline R2* values. On the other hand, hypoxic tumours with low or zero blood volume, due to necrosis, lower microvessel density or due to small vessels, will have lower baseline R2* values because of the lack of delivery of red blood cells to tissues. Attempts have been made to combine blood volume information with R2* maps to improve the sensitivity and specificity for hypoxia detection (Alonzi et al, 2008). Once robust protocols are available, more accurate estimation of the oxygen-enhancing effect of carbogen breathing in prostate cancer may be possible.
Limitations of the BOLD-MRI technique used here are: (1) it does not measure tissue pO2 directly (either in blood or in tissues because of a non-linear relationship of R2* and tissue pO2); (2) images obtained have low signal to noise ratio; (3) the current implementation is single slice, but multislice sequences are now available. The primary advantages of BOLD-MRI are there is no need to administer exogenous radioactive contrast material, and images at high temporal and with high spatial resolution can be obtained and repeated as needed; it is possible to decouple the effects of flow and deoxyhaemoglobin, which are intrinsic to native BOLD images, and so to show the changes in oxygenation independent of changes in the blood flow.
The series of experiments reported in this study show that prostate cancer is amenable to hypoxia modification using carbogen gas breathing. Prostate tumour R2* decreases by an average of 5.8–6.4% in animal models and by 21.6% in human patients as a result of carbogen exposure. These results support the clinical testing of the radiosensitising effect of combining carbogen gas breathing with radiotherapy in prostate cancer.
Change history
16 November 2011
This paper was modified 12 months after initial publication to switch to Creative Commons licence terms, as noted at publication
References
Al-Hallaq HA, River JN, Zamora M, Oikawa H, Karczmar GS (1998) Correlation of magnetic resonance and oxygen microelectrode measurements of carbogen-induced changes in tumor oxygenation. Int J Radiat Oncol Biol Phys 41: 151–159
Alonzi R, Hoskin P (2006) Functional imaging in clinical oncology: magnetic resonance imaging- and computerised tomography-based techniques. Clin Oncol (R Coll Radiol) 18: 555–570
Alonzi R, Padhani AR, Taylor NJ, Stirling JJ, Wilton B, d’Arcy JA, Collins DJ, Saunders MI, Hoskin PJ (2008) Sensitivity and specificity of functional MRI to map tumour hypoxia in the human prostate gland. Proc ISMRM. 16th Annual Meeting (Toronto, Canada): program number 167
Bland JM, Altman DG (1996a) Measurement error and correlation coefficients. BMJ 313: 41–42
Bland JM, Altman DG (1996b) Measurement error proportional to the mean. BMJ 313: 106
Bland JM, Altman DG (1996c) Measurement error. BMJ 313: 744
Blockley NP, Jiang L, Gardener AG, Ludman CN, Francis ST, Gowland PA (2008) Field strength dependence of R1 and R2* relaxivities of human whole blood to ProHance, Vasovist, and deoxyhemoglobin. Magn Reson Med 60: 1313–1320
Brizel DM, Dodge RK, Clough RW, Dewhirst MW (1999) Oxygenation of head and neck cancer: changes during radiotherapy and impact on treatment outcome. Radiother Oncol 53: 113–117
Falk SJ, Ward R, Bleehen NM (1992) The influence of carbogen breathing on tumour tissue oxygenation in man evaluated by computerised p02 histography. Br J Cancer 66: 919–924
Fyles AW, Milosevic M, Wong R, Kavanagh MC, Pintilie M, Sun A, Chapman W, Levin W, Manchul L, Keane TJ, Hill RP (1998) Oxygenation predicts radiation response and survival in patients with cervix cancer. Radiother Oncol 48: 149–156
Gray LH, Conger AD, Ebert M, Hornsey S, Scott OC (1953) The concentration of oxygen dissolved in tissues at the time of irradiation as a factor in radiotherapy. Br J Radiol 26: 638–648
Hill SA, Collingridge DR, Vojnovic B, Chaplin DJ (1998) Tumour radiosensitization by high-oxygen-content gases: influence of the carbon dioxide content of the inspired gas on PO2, microcirculatory function and radiosensitivity. Int J Radiat Oncol Biol Phys 40: 943–951
Hoskin PJ, Sibtain A, Daley FM, Wilson GD (2003) GLUT1 and CAIX as intrinsic markers of hypoxia in bladder cancer: relationship with vascularity and proliferation as predictors of outcome of ARCON. Br J Cancer 89: 1290–1297
Howe FA, Robinson SP, Rodrigues LM, Griffiths JR (1999) Flow and oxygenation dependent (FLOOD) contrast MR imaging to monitor the response of rat tumors to carbogen breathing. Magn Reson Imaging 17: 1307–1318
Kaighn ME, Narayan KS, Ohnuki Y, Lechner JF, Jones LW (1979) Establishment and characterization of a human prostatic carcinoma cell line (PC-3). Invest Urol 17: 16–23
McSheehy PM, Robinson SP, Ojugo AS, Aboagye EO, Cannell MB, Leach MO, Judson IR, Griffiths JR (1998) Carbogen breathing increases 5-fluorouracil uptake and cytotoxicity in hypoxic murine RIF-1 tumors: a magnetic resonance study in vivo. Cancer Res 58: 1185–1194
Mickey DD, Stone KR, Wunderli H, Mickey GH, Vollmer RT, Paulson DF (1977) Heterotransplantation of a human prostatic adenocarcinoma cell line in nude mice. Cancer Res 37: 4049–4058
Movsas B, Chapman JD, Hanlon AL, Horwitz EM, Greenberg RE, Stobbe C, Hanks GE, Pollack A (2002) Hypoxic prostate/muscle pO2 ratio predicts for biochemical failure in patients with prostate cancer: preliminary findings. Urology 60: 634–639
Movsas B, Chapman JD, Horwitz EM, Pinover WH, Greenberg RE, Hanlon AL, Iyer R, Hanks GE (1999) Hypoxic regions exist in human prostate carcinoma. Urology 53: 11–18
Nordsmark M, Overgaard M, Overgaard J (1996) Pretreatment oxygenation predicts radiation response in advanced squamous cell carcinoma of the head and neck. Radiother Oncol 41: 31–39
Overgaard J, Horsman MR (1996) Modification of hypoxia-induced radioresistance in tumors by the use of oxygen and sensitizers. Semin Radiat Oncol 6: 10–21
Parker C, Milosevic M, Toi A, Sweet J, Panzarella T, Bristow R, Catton C, Catton P, Crook J, Gospodarowicz M, McLean M, Warde P, Hill RP (2004) Polarographic electrode study of tumor oxygenation in clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 58: 750–757
Powell ME, Collingridge DR, Saunders MI, Hoskin PJ, Hill SA, Chaplin DJ (1999) Improvement in human tumour oxygenation with carbogen of varying carbon dioxide concentrations. Radiother Oncol 50: 167–171
Rijpkema M, Kaanders JH, Joosten FB, van der Kogel AJ, Heerschap A (2002) Effects of breathing a hyperoxic hypercapnic gas mixture on blood oxygenation and vascularity of head-and-neck tumors as measured by magnetic resonance imaging. Int J Radiat Oncol Biol Phys 53: 1185–1191
Robinson SP, Collingridge DR, Howe FA, Rodrigues LM, Chaplin DJ, Griffiths JR (1999) Tumour response to hypercapnia and hyperoxia monitored by FLOOD magnetic resonance imaging. NMR Biomed 12: 98–106
Robinson SP, Rijken PF, Howe FA, McSheehy PM, van der Sanden BP, Heerschap A, Stubbs M, van der Kogel AJ, Griffiths JR (2003) Tumor vascular architecture and function evaluated by non-invasive susceptibility MRI methods and immunohistochemistry. J Magn Reson Imaging 17: 445–454
Robinson SP, Rodrigues LM, Ojugo AS, McSheehy PM, Howe FA, Griffiths JR (1997) The response to carbogen breathing in experimental tumour models monitored by gradient-recalled echo magnetic resonance imaging. Br J Cancer 75: 1000–1006
Sibtain A, Hill S, Goodchild K, Shah N, Saunders M, Hoskin PJ (2002) The modification of human tumour blood flow using pentoxifylline, nicotinamide and carbogen. Radiother Oncol 62: 69–76
Stone KR, Mickey DD, Wunderli H, Mickey GH, Paulson DF (1978) Isolation of a human prostate carcinoma cell line (DU 145). Int J Cancer 21: 274–281
Taylor NJ, Baddeley H, Goodchild KA, Powell ME, Thoumine M, Culver LA, Stirling JJ, Saunders MI, Hoskin PJ, Phillips H, Padhani AR, Griffiths JR (2001) BOLD MRI of human tumor oxygenation during carbogen breathing. J Magn Reson Imaging 14: 156–163
Teicher BA, Schwartz GN, Dupuis NP, Kusomoto T, Liu M, Liu F, Northey D (1994) Oxygenation of human tumor xenografts in nude mice by a perfluorochemical emulsion and carbogen breathing. Artif Cells Blood Substit Immobil Biotechnol 22: 1369–1375
Tomlinson R, Gray L (1955) The histological structure of some human lung cancers and the possible implications for radiotherapy. Br J Cancer 9: 539–549
Wang JZ, Li XA, Mayr NA (2006) Dose escalation to combat hypoxia in prostate cancer: a radiobiological study on clinical data. Br J Radiol 79: 905–911
Acknowledgements
We thank Ben Wilton who developed the DiffusionView analysis software.
Funding: Cancer Research UK (Programme Grant C39/A3987). The funding source had no role in the design of the study, collection, analysis, interpretation of the data, writing of the report or decision to publish.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
From twelve months after its original publication, this work is licensed under the Creative Commons Attribution-NonCommercial-Share Alike 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/3.0/
About this article
Cite this article
Alonzi, R., Padhani, A., Maxwell, R. et al. Carbogen breathing increases prostate cancer oxygenation: a translational MRI study in murine xenografts and humans. Br J Cancer 100, 644–648 (2009). https://doi.org/10.1038/sj.bjc.6604903
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.bjc.6604903
Keywords
This article is cited by
-
Value of blood oxygenation level-dependent magnetic resonance imaging in early evaluation of the response and prognosis of esophageal squamous cell carcinoma treated with definitive chemoradiotherapy: a preliminary study
BMC Medical Imaging (2024)
-
Feasibility of blood oxygenation level-dependent MRI at 3T in the characterization of hepatic tumors
Abdominal Imaging (2014)
-
BOLD-MRI of breast invasive ductal carcinoma: correlation of R2* value and the expression of HIF-1α
European Radiology (2013)
-
Clinical implications of skeletal muscle blood-oxygenation-level-dependent (BOLD) MRI
Magnetic Resonance Materials in Physics, Biology and Medicine (2012)
-
Functional magnetic resonance: biomarkers of response in breast cancer
Breast Cancer Research (2011)