Introduction

Over the past years, the field of neuromorphic devices or synaptic electronics has attracted a great deal of attention1. Efforts in this field have concentrated on capturing the computational efficiency of the brain by reverse-engineering it at the hardware level. In the past years, a host of neural processing functions have been demonstrated with neuroinspired devices such as short- and long- term plasticity, short- to long-term memory transition, dynamic filtering and Spike-Timing-Dependent Plasticity, just to name a few2,3,4,5,6,7. It is well known that information processing in the brain is spatiotemporal in nature: spatial and temporal dynamics in the brain contribute to a continuum that unfolds in space and time, resulting in higher complexity neural network functionalities, for example time encoding in neural trajectories8. A well known paradigm of spatiotemporal processing is the orientation selectivity of cortical cells9. Orientation selectivity is a broadly investigated phenomenon that refers to vision. Hubel and Wiesel pioneered the understanding of visual perception through their early work on the feline visual cortex10,11,12. Visual cortex cells are known to change their output spiking rate selectively to light bars with differing orientation. According to Hubel and Wiesel’s theory, the receptive field of visual cortex cells has a center/surround shape (a central and a surrounding region) that consists of an excitatory (ON) and an inhibitory (OFF) region, which produce ON/OFF (ON central and OFF surrounding) or OFF/ON (OFF central and ON surrounding) center/surround structures. When these center/surround structures are superimposed into elongated forms, they produce selectivity towards a specific orientation. Although the basic model of orientation selectivity is currently well understood, there are still uncertainties about the underlying mechanisms13. Orientation selectivity has been recently demonstrated with neuromorphic devices and/or arrays of devices such as with memristive grids14, floating-gate transistor arrays15 and graphene oxide transistors16.

Another field of particular interest that is related to biology and has recently attracted a lot of interest is the field of organic bioelectronics17,18. A wide variety of organic bioelectronic devices is available for interfacing with biological systems including neural interfaces, drug delivery devices, biosensors, devices that control cell growth and enzyme-based logic devices19,20,21,22,23. The organic electrochemical transistor (OECT) is regarded as a benchmark in organic bioelectronics24,25. An OECT consists of an electrolyte between a gate electrode and a conducting polymer channel. The polymer channel can be gated through the electrolyte. By applying a gate voltage, ions from the electrolyte are injected to the channel and change the doping level of the conducting polymer. This leads to the modulation of the electronic current that flows through the channel. OECTs have several attractive characteristics for interfacing with biological systems including the efficient ionic-to-electronic current transduction, operation in a liquid electrolyte environment, mechanical flexibility and biocompatibility. Moreover, the channel of the OECT can be laterally gated with an electrode (i.e., the gate electrode)26,27. OECTs have also been recently proposed as neuromorphic devices27,28,29 and neural functions that are temporal in nature have been demonstrated in a single device level, such as short- and long-term synaptic plasticity27,28. In these devices, depending on the presynaptic timing and voltage conditions, various synaptic plasticity functions were reproduced, but without any spatial variable. Here, we demonstrate for the first time the implementation of a spatially-correlated neuromorphic function in a poly(3,4-ethylenedioxythiophene) doped with poly(styrene sulfonate) (PEDOT:PSS) based OECT. This spatially-correlated function is an analogue of orientation selectivity in a single device level. Spatially-correlated functions similar to orientation selectivity may pave the way for introducing spatial concepts in the implementation of neuromorphic functions with multi-terminal neuromorphic devices that share a common electrolyte.

Results

The device geometry used here is depicted in Fig. 1a. The device fabrication process is described in detail in the experimental section. A glass substrate with patterned Au electrodes (source, drain electrode and an array of 3 × 3 gate electrodes) was coated with a PEDOT:PSS film in order to define a device channel with nominal dimensions of 15 mm × 0.5 mm (length × width, L × W). PEDOT:PSS was used to make the channel, as this material has been established as the standard for high performance OECTs. The device was laterally gated through a NaCl electrolyte confined in a PDMS well, with a grid of 3 × 3 gate electrodes at coordinates (x, y). For the experiments, various voltage pulses were applied at the (x, y) gate electrodes (with amplitude VP and width tP). The resulting drain current ID was simultaneously recorded and its amplitude I0 for t → 0 was defined in each case (see also Fig. 1c). The geometry of the multi-gated device was inspired by the visual system structure15,30,31. The analogy of the multi-gated OECT and the visual system is presented in Fig. 1a,b. In the visual system (Fig. 1b), optical stimuli are captured by the retina and then transmitted as optical information to the Lateral Geniculate Nucleus (LGN) cells of the thalamus via optic nerves. The information from the LGN cells is subsequently transmitted to the orientation-selective visual cortex cells in a purely electrical and/or chemical form. At that stage, the activity of a group of LGN cells (this group is also known as receptive field) is projected to a cortical cell and transformed into an orientation–dependent firing activity. In the multi-gated OECT device of Fig. 1, the (x, y) gate electrodes are regarded as the receptive field of a visual cortex cell, while the drain current ID is an analogue of the activity of the cortical cell. In the multi-gated OECT, as in the case of the neural transmission from the thalamus to the cortical neurons, there is a projection from a spatial input voltage pattern of (x, y) gate inputs (that can be regarded as a vector field) into a single I0 output response (that can be regarded as a scalar quantity).

Figure 1
figure 1

Analogy of the visual system and the multi-gated OECT.

(a) Schematic of the multi-gate OECT device. (b) Simplified schematic of the visual system. The analogy of the multi-gated OECT and the thalamus/visual cortex is also depicted in Fig. 1a,b. (c) Measurement of the drain current ID that results from a voltage pulse VP at a gate electrode and the definition of drain amplitude I0.

Initially a voltage pulse (VP = 0.3 V, tP = 50 ms) was applied at each (x, y) gate electrode and I0 was recorded (for source-drain voltage VDS = −0.2 V). The experimental spatial I0 mapping of the multi-gated OECT is presented in Fig. 2a. The spatial mapping was constructed by pulsing each (x, y) gate electrode and measuring I0 for each case. From the spatial mapping, an increased I0 amplitude is obvious for the gates that are closer to the drain electrode. As described in the Supplementary Information section, from the time domain response of the equivalent circuit that describes the OECT (see also Supplementary Fig. S1 for the equivalent circuit), the amplitude I0 (for t → 0) can be expressed as I0 = V/RE (equation S13 of Supplementary Information), where V is the input pulse amplitude and RE the electrolyte resistance between the gate electrode and the PEDOT:PSS channel. Equation S13 implies that I0 depends on RE. RE can be simply expressed using the equation S14, as RE = ρE (d/A), where ρΕ is electrolyte resistivity, A is the electrode area and d is effective distance between the channel and the center of the (x, y) gate electrode. As shown in Supplementary Figs S2 and S3, this increased I0 response close to the drain electrode is attributed to the decrease of the electrolyte resistance RE for smaller gate-drain electrode distances d. This spatial inhomogeneity in I0 can be used for implementing the orientation selectivity function in multi-gated OECTs.

Figure 2
figure 2

Spatial mapping of current amplitude and relaxation time.

Spatial mapping of: (a) the resulting amplitude I0 of the drain current and (b) the relaxation time tR. Each (x, y) gate electrode was pulsed separately with a voltage amplitude VP = 0.3 V, time width tP = 50 ms and the resulting current was measured for VDS = −0.2 V.

The relaxation time tR for the depolarization response of the drain current ID is also calculated for pulsing every (x, y) gate using a simple exponential decay, I(t) ~ exp[−t/tR] and the results are presented in Fig. 2b as a spatial mapping of tR. Similarly with the I0, inhomogeneity towards the drain electrode is also evident in tR mapping. For example the closest to the drain, gate electrode (x = 1, y = 1), results in the lowest tR value. Assuming that polarization and depolarization responses are symmetrical (implying that the same equivalent circuit describes both processes), equation S11 of Supplementary Information gives a relaxation time that for RE RP can be simplified to tR = RE∙CP;32 where CP is the PEDOT:PSS capacitance. Therefore the closest gate to the drain electrode, defines the lowest RE, results also in the lowest relaxation time tR.

Spatial patterns of input voltage can be created by superimposing gate pulses at more than one (x, y) electrode. As shown in Fig. 3a, a spatial pulse of variable orientation is reproduced by applying voltage pulses (VP = 0.3 V, tP = 50 ms) concurrently at 3 different gate electrodes. For example, an orientation of 0° can be defined by applying pulses at the (x = 1–3, y = 2) electrodes, while orientation of 45° can be defined by applying pulses at the (x = 1–3, y = x) electrodes. Spatial voltage orientations from 0° to 180° with a step of 45° can be produced with an amplitude I0 defined for each orientation (for source-drain voltage VDS = −0.2 V). The results are presented in Fig. 3b as a polar diagram of the increased percentage of I0 with respect to the lowest reference amplitude I0,R (at 0° or 180°). The output amplitude I0 depends on the orientation of the spatial pulse pattern, with an increase of almost 60% in respect to I0,R for the orientation of 45°. The spatial orientation of the input pulse is “encoded” in the form of a single output I0 response of the multi-gated OECT. This represents an analogy with the visual system, where a receptive field of the thalamus is projected onto a single visual cortex cell. The polar diagram of I0 exhibits an orientation selectivity towards the drain electrode, i.e., 45°. This selectivity towards 45° is attributed to a superimposed spatial pulse that includes the closest to the drain, gate electrode (x = 1, y = 1), which produces the maximum I0 amplitude since it defines the lowest resistance RE (also refer to the experimental I0 spatial mapping of Fig. 2a or the corresponding theoretical mapping of Supplementary Fig. S3d).

Figure 3
figure 3

Orientation selectivity.

(a) Definition of input spatial pulse patterns with different orientations (0°–180°) at the (x, y) gate electrodes. The spatial patterns are defined by applying pulses simultaneously at 3 gate electrodes (VP = 0.3 V, tP = 50 ms). (b) Polar diagram of the percentage increase of I0, %(I0–I0,R)/I0,R. for different spatial orientations of the input pulse. (c) Polar diagram of the relaxation time tR of the depolarization drain current for different spatial orientations of the input pulse.

The measured time tR for the depolarization response of the drain current ID is also calculated for the various spatial orientations of the input voltage and the results are presented in Fig. 3c as a polar diagram of tR. Similarly, relaxation time selectivity towards 45° is also evident on the polar diagram of tR. Orientation of 45° produces the lowest tR value, that is almost 50% lower than the other orientations. Again the spatial pulse of 45° includes the closest to the drain, gate electrode (x = 1, y = 1) and therefore results in the lowest relaxation time tR. It should be mentioned that spatial configurations other than 45°, such as (x = 1–3, y = 1) or (x = 1, y = 1–3), also result in maximum I0 and minimum tR, but these configurations are not used here for demonstration because they do not define any spatial orientation of the input pulse in respect to the central gate with coordinates (x = 2, y = 2).

Discussion

We have demonstrated a sensing phenomenon analogous to orientation selectivity from the thalamus to the visual cortex with OECTs and electric stimuli as an input. It should be mentioned that cortical orientation maps already exist at the very early postnatal period, even in the absence of visual inputs and are later strengthened by visual stimuli33,34. This work represents an ionic analogue of previsual orientation selectivity in a single OECT device. This approach differs from the existing approaches to orientation selectivity without an optical stimulus, in which grids of memristive devices14, or arrays of floating gate transistors are used15. In these works, orientation functionality is constructed by mapping the grids or arrays of several devices (e.g., mapping of resistance change in a memristive grid). A more complete, yet simplified model of orientation selectivity could be produced in future devices by integrating photodiodes at the gate electrodes in order to add spatially selective optical sensitivity. Orientation selectivity would be tuned by increasing the distance of the (x, y) gates from the PEDOT:PSS channel, or by using a channel with smaller dimensions. For example, the gates appear as point electrodes for large gate-channel distances and spatial mapping of I0 becomes more homogeneous. Moreover, two channels might also be placed perpendicular to each other and would therefore be selective to different orientations of the spatial pulses of the (x, y) gate electrodes. This spatially-correlated function would have many potential applications, including the detection of ionic moving fronts and oriented ionic fluxes35, or spatially mapping ionic concentrations such as pH gradients36.

Summary

In conclusion, a spatially-correlated function that was inspired by the visual system was reproduced in a single multi-gated OECT device. Gating the device in a global electrolyte permits a “soft-wired” and weighted connection of a single channel with spatially distributed multiple gate inputs and the device exhibits orientation selectivity with respect to spatially oriented voltage inputs. These results pave the way for organic bioelectronic applications with spatially resolved functionalities in processing and sensing.

Methods

Device fabrication

The devices were made using standard microfabrication techniques. As substrates, 26 mm × 76 mm glass slides were used. The contact lines were defined by evaporating a 10 nm Cr and a 100 nm Au layer on top of pre-patterned photoresist and a subsequent soaking in an acetone/isopropanol bath to remove the excess material. The Cr layer is needed to enhance surface adhesion between glass and Au. To protect the contact lines from the electrolyte, two parylene C layers were deposited on top, with 2 μm thickness each. The first was deposited on a surface treated with silane to enhance adhesion with the substrate and a thin 2% soap solution layer was spin-coated before the second deposition. This allows to peel-off the upper layer, thereby defining the device active area. The polymer used in this communication was PEDOT:PSS [Clevios PH 1000 from Heraeus Holding GmbH, with 5 wt% ethylene glycol, 0.1 wt% dodecyl benzene sulfonic acid and 1 wt% of (3-glycidyloxypropyl)trimethoxysilane)]. It was used both as the channel and as the gate. The desired film thickness (~500 nm) was obtained by three subsequent spin-coating steps with varying rotation speeds of 1500, 650 and 650 rpm respectively. A second photolithographic step was used to pattern these features. PEDOT:PSS spin-coating was followed by a hard-bake step at 140 °C for 60 min. The squared gate electrodes had an area of 3000 × 3000 μm2. Metal interconnects, insulated with parylene C, were used to make electrical contact. For detailed gate-channel distance mapping, refer to Figure S3a of the Supplementary Information section.

Device characterization

The transistor was gated with (x, y) lateral Au electrodes covered with PEDOT:PSS and aqueous NaCl electrolyte (100 mM) in deionized water. All measurements were recorded after cycling the OECTs (repetitive 0.3/−0.3 V cycles at the gate for 10 sec each) in order to obtain reproducible behavior. Each current amplitude I0 was defined for pulsing each gate with tP = 50 ms and TP = 10 s (using the average of 5 pulses) and recording the drain current. The amplitude I0 was quite stable for 5 pulses. When the devices are operated in normal conditions (using VDS < 0.6 V and VP < 0.6 V), they are quite stable for at least a six month period. OECT dimensions (PEDOT:PSS channel width, length and gate electrode) were determined with optical microscopy. The thickness of the PEDOT:PSS film was determined with profilometry. The drain current was measured using a National Instrument PXIe-1062Q system. The OECT was biased with a PXIe-4145 source measure unit (SMU) that was simultaneously recording drain current with a sampling rate of 1kHz. Gate voltages were generated by a National Instrument USB-6259. Both gate voltages and drain current measurements were internally triggered by the PXIe system. The acquisition system was monitored by custom-made LabVIEW software.

Additional Information

How to cite this article: Gkoupidenis, P. et al. Orientation selectivity in a multi-gated organic electrochemical transistor. Sci. Rep. 6, 27007; doi: 10.1038/srep27007 (2016).