Introduction

Implementing a fault-tolerant quantum processor requires gate fidelities far exceeding a threshold of 99%1,2,3,4. In superconducting qubits, these gates are realized by on or near-resonant microwave pulses5. However, on the way to the circuit, the shape of these pulses is distorted by multiple passive microwave components such as attenuators, circulators and wires. These distortions negatively affect the gate fidelities if they are not accounted for.

The collective response of all microwave components to an incident signal is described by the transfer function of the system. If the transfer function is known, digital signal processing techniques allow for full control over the shape of applied pulses. However, since superconducting circuits are embedded in a cryogenic environment operated at millikelvin temperatures, the transfer function from pulse source to sample is not accessible with conventional network analyzers. In the past, this problem has been tackled by different calibration methods, which are usually limited to specific pulse shapes6 or systems7. While more general pulse optimization schemes have been proposed theoretically, they have yet to be implemented in a real quantum system8,9,10.

In recent years, the growing interest in quantum sensors11,12,13 has facilitated a more direct approach, where the signal arriving at the circuit is probed directly. In particular, superconducting qubits have been successfully employed as photon sensors due to their high electrical dipole moment. While sensing based on a variety of physical phenomena such as the cross-Kerr effect14, occurrence of the Mollow triplet15 or electromagnetically induced transparency16 has been shown, these methods are limited to the discrete frequencies of the qubit transitions. An alternative approach operates a qubit as a vector network analyzer, but only works in the MHz regime17. Recently, Schneider et al. demonstrated that the ac Stark effect in anharmonic multi-level quantum systems (qudit) can be used to detect on-chip microwave fields18. Here, signals over a range of more than one GHz were measured. When including higher levels19, this sensor can simultaneously determine the amplitude and frequency of an unknown signal, promoting it as a useful tool for experiments in quantum optics20,21,22 and quantum microwave photonics23,24,25, where in-situ frequency detection can be beneficial. However, the spectroscopic measurement techniques employed in these proof of principle experiments offer limited precision for reasonable data acquisition times.

In this work, we investigate the potential of the type of sensor used in ref. 18 to characterize the microwave transmission from source to sample. We use a time-resolved measurement setup to boost the sensor performance by an order of magnitude. By applying a well known microwave signal, we probe the amplitude of the transfer function over a wide frequency range. Finally, we estimate the errors and limits of our sensing scheme and discuss the potential for further improvement.

Results

The sensor we use in our experiments is a non-tunable superconducting transmon (ω1/2π = 4.685 GHz) with a concentric design26. The transmon architecture offers a low anharmonicity (280 MHz), which is beneficial for probing higher qudit transitions, as well as an enhanced dipole moment, which increases the sensitivity to local ac fields27. To allow for manipulation (PG, ωG) and readout (via a resonator) of the qudit, the sample is connected to a time resolved measurement setup (Fig. 1a). An additional microwave source with frequency ωF and power PF was installed to generate a on-chip field with amplitude \({A}_{\text{F}}\propto \sqrt{1{0}^{{P}_{\text{F}}/10\text{dBm}}}\). Neglecting the readout resonator, the Hamiltonian describing our system reads

$$\begin{array}{ll}H/\hslash =\mathop{\sum }\limits_{i}\frac{{E}_{i}}{\hslash }\left|i\right\rangle \left\langle i\right|+{A}_{\text{G}}(t)(\hat{b}+{\hat{b}}^{\dagger })\cos {\omega }_{\text{G}}t +{A}_{\text{F}}(\hat{b}+{\hat{b}}^{\dagger })\cos {\omega }_{\text{F}}t,\end{array}$$
(1)

where the anharmonic annihilation and creation operators \(\hat{b}\) and \({\hat{b}}^{\dagger }\) take the different coupling strengths to the transmon levels into account, which are expressed in their Eigenbasis \(\left|i\right\rangle\). The Eigenenergies Ei are calculated from the exact solution of the Transmon Hamiltonian27. In the following, we label the qudit transitions ωi = EiEi−1 and their associated parameters with identical indices.

Fig. 1: Experimental setup and methods.
figure 1

a Schematic diagram of the transmon qudit sensor and readout resonator (coplanar waveguide) connected to the employed microwave setup. The gate (PG, ωG) and readout (PM, ωM) pulses are merged with the continuous tone (PF, ωF) which creates the on-chip microwave field to be measured. The combined signals are repeatedly attenuated within the cryostat before reaching the sample mounted at the 25 mK stage. b Graphical representation of the sensor measurement procedure. As the qudit transitions ωi (i = 1, 2) are shifted in the presence of a microwave field, the frequency ωR,i of the corresponding Ramsey oscillations changes, here exemplified for ω1. Ramsey fringes thus reveal the magnitude of these level shifts. Together, the shifts of the first two qudit levels can be used to extract the amplitude and frequency of the microwave field.

To detect the amplitude and frequency of an on-chip microwave field we determine the ac Stark shift Δi that it induces in the first and second qudit transition (i = 1, 2). A simple but precise way to measure those shifts are Ramsey fringes28,29. The overall idea of the measurement scheme is sketched in Fig. 1b. Generally, performing Ramsey interferometry for a specific transition produces oscillations in the population of the associated qudit states. In the absence of an external field, the frequency of these oscillations simply depends on the frequency mismatch between the respective qudit transition and the applied gate tone ωG,i. However, if the qudit is subjected to a microwave field, this mismatch changes due to the ac Stark effect. The shift of any qudit transition

$${\Delta }_{i}={\omega }_{\text{R},i}-({\omega }_{\text{G},i}-{\omega }_{i}),$$
(2)

can then be calculated from the oscillation frequency ωR,i corresponding to the respective Ramsey fringes, as long as the unperturbed qudit frequencies ωi are known.

Figure 2 shows Ramsey oscillations of the first and second qudit transition when applying a field with ωF,apl/2π = 5.285 GHz and PF,apl = 4 dBm. In the experiments, a π-pulse prior to the Ramsey sequence allows probing the frequency shift of the second excited state. An identical π-pulse after the sequence increases the visibility and removes the spurious signal of the relaxation to the ground state. For these π-pulses to be on resonance with the shifted transition frequency \({\tilde{\omega }}_{1}={\omega }_{1}-{\Delta }_{1}\), knowledge of Δ1 is required. Consequently, the order in which the qudit transitions are probed is fixed. To determine the frequencies of the Ramsey oscillations, we fit the data with an exponentially damped sine function, which also accounts for the additional decay channels of higher lying qudit levels30 via a declining amplitude offset. This decay of the higher excited level also limits the maximum Ramsey delay time Δt used in our experiments (see Supplementary Information for details).

Fig. 2: Employed sensing scheme.
figure 2

First, the shift of the first qudit transition Δ1 is determined from the frequency of the corresponding Ramsey oscillations. Second, Δ1 is used to adjust the resonant π-pulse which excites the qudit to the \(\left|1\right\rangle\) state. Then, an additional Ramsey experiment is performed between \(\left|1\right\rangle\) and \(\left|2\right\rangle\) measuring Δ2. Third, Δ1 and Δ2 are processed by a pair of lookup tables to determine the frequency and amplitude of the microwave field causing the shifts. Here, only the lookup table for Δ1 is shown. The sensor limits depicted within the lookup table are derived in the main section.

Lacking a closed analytical solution, the ac Stark shifts Δi calculated from ωR,i are then evaluated with a pair of lookup tables. Each lookup table contains the expected shifts of the respective qudit transition for various microwave fields. Searching both lookup tables simultaneously for the entries that are closest to our measurement data yields an unambiguous result for the frequency and amplitude of the detected field. In ref. 18, these lookup tables are generated analytically by modeling the transmon as an anharmonic oscillator. The field dependent level shifts are then calculated from perturbation theory. However, we find that this simplified model is no longer accurate when detecting frequency shifts with a precision of a few kilohertz. We therefore rely on numerical simulations of the exact transmon Hamiltonian (Eq. (1), see Methods for details).

The last plot in Fig. 2 shows the numerically generated lookup table for the first qudit transition, illustrating the dependency of the ac Stark shift on the amplitude and frequency of the microwave field. Here, a black and white line represent the upper and lower limit of the sensor, respectively. These limits originate from the restricted number of measurement points for the Ramsey fringes and will be discussed in detail later. Evaluating the data in Fig. 2 we find microwave photons of frequency ωF,ex/2π = 5.297 GHz arriving at the qudit at a rate of AF,ex/2π = 0.097 GHz, which corresponds to a power of PF,ex = AF,ex\(\hbar\)ωF,ex = −116.7 dBm.

The full sensing scheme proposed in this work can be summarized as a three step process. After measuring the shift of the first and second qudit transition using Ramsey fringes, the field parameters are extracted from the measurement data with the help of pre-calculated lookup tables. To verify the scheme, we apply a well known microwave signal with constant power and gradually increase the frequency over a range of 450 MHz. We probe the field arriving on-chip with our sensor and plot the extracted ωF,ex over the applied frequencies ωF,apl (Fig. 3a), finding a good agreement. Plotting AF,ex over the same axis yields the amplitude of the transfer function (Fig. 3c). Here, we observe a strong frequency dependence, dominated by the readout resonator operating as a filter and cable resonances, which demonstrates the significance of calibrating microwave lines.

Fig. 3: Sensor performance analysis.
figure 3

a Comparison between the frequencies applied with the microwave source (ωF,apl) and the frequencies extracted from the sensor (ωF,ex). The shaded area indicates the uncertainty estimated from the standard errors to the Ramsey fits. b The magnitude of the discrepancy between ωF,apl and ωF,ex is an indicator for the reliability of our measurements. c Amplitude of the transfer function for a signal with constant power PF,apl = 4 dBm. d Ramsey standard errors used for the calculation of the uncertainty in a and c. The values are extracted from the same fits as the sensor data. e Standard errors as a function of the number of averages. For this experiment, Navg = 3000 averages were used (indicated by the arrows).

Shaded areas in Fig. 3 illustrate the uncertainty of our results. The uncertainty is estimated from varying our experimentally determined value of Δi by ±σR,i, where σR,i is the standard error of ωR,i resulting from the fit. In our case, σR,i is a consequence of the limited signal to noise ratio (SNR) during the measurement of individual data points and therefore depends on the number of averages Navg used in the experiments. As shown in Fig. 3e, the experimentally measured decline of σR,i is well fitted by \({{\rm{a}}}_{i}/\sqrt{{N}_{\text{avg}}}+{{\rm{c}}}_{i}\) (see also Supplementary Information), as expected from the shot noise limit31. In the interest of keeping the measurement time comparable to ref. 18, all experiments were performed at Navg = 3000, fixing the errors at around σ/2π = 10 kHz, see Fig. 3d. On average, this amounts to a relative uncertainty for the amplitude and frequency of ΔAF/AF = 4% and ΔωF/ωF = 0.5%, respectively. This error increases for higher frequencies, as Δi decreases for large detuning between microwave field and qudit, while the magnitude of σR,i remains unchanged.

Another potential source of noise, which has not been considered in the calculation above, are temporal fluctuations of the qudit transition frequencies Δi due to unstable two-level systems (TLS)32,33,34,35. To quantitatively estimate their influence, we theoretically study the following example, where the first transition frequency is shifting by Δω1 = 20 kHz34 right before a sensor measurement. Then, subsequent π/2-pulses are even further detuned and the corresponding Ramsey frequency will be altered, resulting in an offset for Δ1 by ±Δω1. Processing this offset together with the presented measurement data, we find that this causes an uncertainty for the extracted frequencies of \(\overline{\Delta }{\omega }_{\text{F}}/2\pi =16.8\ \,\text{MHz}\,\). Note that this uncertainty is independent from our evaluation of σR,i, as the shift of the transition frequency affects all data points equally. This rough estimation thus provides a reasonable explanation for the few data points, where the discrepancies δ between ωF,ex and ωF,apl exceeding the estimated error bars in Fig. 3b. While a more profound analysis of this effect is challenging due to the varying timescales on which these fluctuations can occur, their influence could be mitigated in future measurements by a continuous recalibration of the qudit transition frequencies, i.e, adjusting the drive frequency to the fluctuating qudit transition frequencies.

In the following, we address the limits of our sensor (see Supplementary Information for an extended analysis). As discussed in ref. 18, it is practical to limit the ac Stark qudit sensor to fields that are higher in frequency than the first qudit transition. Otherwise, the microwave field is more likely to excite higher qudit states. In this work, using Ramsey fringes results in additional constrains for the range of the sensor. The three parameters defining the total measurement time for a Ramsey experiment are the maximum delay time between the π/2-pulses \(\Delta {t}_{\max }\), the number of time steps NR and the passive reset time Trep. To reduce the measurement time together with the chance of encountering frequency fluctuation34, it is desirable to minimize these parameters. At the same time, the sampling rate \(f={N}_{\text{R}}/\Delta {t}_{\max }\) should be large enough to resolve the Ramsey oscillations clearly. Here, we find that values more than five times larger than the minimum value stated by the Nyquist-Shannon theorem36,37 yield accurate fits. To ensure correct fitting of the data, it is also desirable to represent at least one full oscillation period within the measurement interval, which requires a sufficiently large \(\Delta {t}_{\max }\).

When operating the sensor with gate pulses that are on resonance with the unperturbed qudit frequency, Eq. (2) simplifies to Δi = ωR,i and we can write the limits for the detectable frequency shifts as

$$\begin{array}{l}{\Delta }_{1}/2\pi\,<\,{N}_{\text{R}}/(5\cdot 2\Delta {t}_{\max })=10\ \,\text{MHz}\,\\ {\Delta }_{2}/2\pi\,>\,1/(\Delta {t}_{\max })=1.25\ \,\text{MHz}\,,\end{array}$$
(3)

for NR = 80 and \(\Delta {t}_{\max }=800\ \,\text{ns}\,\). Together with Trep = 240 μs and Navg = 3000, all parameters amount to a total measurement time of \(\sim\!1\ \min\). Note that the lower limit in Eq. (3) is given by Δ2, which is always a stronger constraint than Δ1. The lookup table in Fig. 2 visualizes the set of detectable microwave fields determined by these limits. When a different range is required, they can be adjusted by choosing ωG,iωi or by changing the Ramsey parameters.

Discussion

We have successfully implemented a sensor for microwave fields based on time-resolved measurements of the ac Stark shift. Employing Ramsey fringes, we harness the high sensitivity of the qudit phase on the frequencies of the first and second qudit transition. Evaluating the measured shifts with numerically generated lookup tables yields the amplitude and frequency of the applied microwave field. Using this sensing scheme, we measure the amplitude of the transfer function over a range of several hundreds of MHz. The results were validated by comparing the frequencies of the applied microwave tone with the sensor output. In comparison to the previous implementation by Schneider et al.18, we were able to increase the precision by an order of magnitude to \(\overline{\Delta }{A}_{\text{F}}/2\pi =3.4\ \,\text{MHz}\,\) and \(\overline{\Delta }{\omega }_{\text{F}}/2\pi =25\ \,\text{MHz}\,\) for comparable measurement times. While a full pulse calibration requires similar measurements for the phase of the transfer function (see Supplementary Information for theoretical considerations), our results may already prove useful for advancing the control over hybrid microwave systems38 and could enable broadband microwave detection in superconducting particle detectors39,40.

In the future, employing parametric amplifiers41,42,43 and active reset44,45,46 could reduce the measurement time of the sensor to a few seconds while simultaneously improving the precision. Moreover, advanced quantum sensing protocols that use linear slope detection over an extended dynamic range can be used to further increase the precision47,48,49.

Methods

Experimental setup

We use a standard cQED setup consisting of a transmon qudit (ω1/2π = 4.685 GHz and ω2/2π = 4.405 GHz) capacitively coupled to a λ/2-wavelength coplanar waveguide resonator (ωr/2π = 6.878 GHz). To fabricate the resonator and the large-scale components of the transmon, thin-film NbTiN is used, whereas the Josephson tunnel junction consists of a conventional Al/AlOx/Al stack50. The chip is placed in a copper sample box and cooled down to temperatures below 25mK in a wet dilution refrigerator.

The microwave gate pulses for the Ramsey sequence are generated in a single-sideband mixing scheme, using local oscillators and arbitrary waveform generators (AWG). Combined with the permanent microwave tone generating the on-chip field, these pulses are repeatedly attenuated on different temperature stages of the cryostat before reaching the sample. We use the resonator to dispersively readout the state of the qudit51,52. The readout signal is downconverted, digitized, and interpreted by our measurement software.

Lookup table calculations

Based on the full system Hamiltonian in Eq. (1), we perform master-equation simulations using the QuTip package53,54. Starting with the transmon in the ground (excited) state \(\left|0\right\rangle\) (\(\left|1\right\rangle\)), we compute the full time evolution while applying a Ramsey sequence by temporarily switching on AG(t) in the simulation. After computing each point of the Ramsey fringes, Δ12) is determined by fitting the oscillations. This process is repeated for varying field amplitudes AF and frequencies ωF, gradually filling the lookup table.