Introduction

Newborn screening (NBS) is a well-established public health service in many countries [1]. NBS enables early detection and treatment of a wide variety of diseases by analyzing metabolites, hormones, and enzyme activities, using dried blood spots (DBS). Sampling of the DBS occurs 1–2 days after birth. In NBS, diseases should only be screened for, if specific treatment is available [2,3,4]. Based on the often-cited Wilson and Jungner criteria [4], another principle of NBS is not to report unaffected carriers.

Spinal muscular atrophy (SMA; OMIM #: 253300) is a severe, autosomal-recessive neuromuscular disease, characterized by the degeneration of α-motor neurons [5, 6]. The Caucasian population shows an incidence of 1:6000–1:10,000 [5,6,7], with estimates for Germany up to 1:4000 [8]. Based on direct genetic testing of SMN1 copies in a control population in Germany, a carrier frequency of 1:35 was found, resulting in an incidence of 1:4900 [9].

SMA is primarily caused by variants in the survival motor neuron (SMN) gene. The gene consists of nine exons and encodes a 38-kD SMN protein, which plays a key role in the assembly and regeneration of small nuclear ribonuclear proteins, mRNA splicing, and axonal RNA transport. The SMN gene is located on chromosome 5 containing two highly homologous copies of SMN, a telomeric (SMN1) and a centromeric copy (SMN2) that differ by five bases altogether (Fig. 1) [10,11,12]. The transcription of SMN1 results in full-length mRNA. In contrast, SMN2 transcription generates a shortened mRNA lacking exon 7 (c.840C>T, a paralog sequence variant; Supplementary Table 1) with a small amount of full-length transcript also generated (Fig. 1).

Fig. 1
figure 1

Schematic overview of the SMN-coding genes. SMN1 is encoded on chromosome 5 by nine exons (exons 2 and 3 are usually referred to as exon 2a and 2b, respectively [12]). Exon 7 (the eighth exon) is missing in most SMA patients, and is missing from SMN2 transcripts as well. SMN1 and SMN2 only differ by five nucleotides as indicated [c.835-44G>A (rs1454173648); c.840C>T (rs1164325688); c.888+100A>G (rs212214); c.888+215A>G (rs1244569826); c.1155G>A (rs1208416968)]. All variants shown are described using the NM_000344.3 transcript reference sequence based on NG_008691.1 for intron positions. Primers and probes for the c.840 site are indicated in gray; the site itself is indicated by a gray square in the forward primer

Ninety-five percent of SMA-affected individuals have a homozygous deletion involving SMN1 exons 7 and 8, or exon 7 only. The latter is true for around 5%, and represent SMN1/SMN2 hybrid genes [10,11,12,13]. Further, disease-causing variants, like subtle variants (3.4%) and no de novo variants (2%) in the SMN1 gene, contribute to the incidence [14, 15]. The SMN2 gene is unable to compensate for the homozygous loss of SMN1, but SMN2 copy number is a well-established modifier on the variable SMA phenotype [5, 6, 9, 10].

SMA is classified into different phenotypes, based on the age of onset and the motor function achieved. SMA type I is the most severe and common type, which accounts for about 50% of patients. Life expectancy is generally considered to be <2 years, due to the rapid progression of muscle weakness and respiratory failure [5, 6, 16]. Although a therapy has recently become available [5, 6, 17,18,19,20], the success of this therapy strongly depends on early intervention, because substantial loss of motor neurons occurs by 3 months of age and progresses during the course of the disease [16, 21]. Only a genetic test allows identification before the onset of symptoms and offers a treatment in time.

Challenges presented by NBS genetic testing include the extraction of sufficient DNA and selection of an appropriate assay to detect the SMN1 deletion. The pitfall in selecting an appropriate assay for SMN1 deletions is the high homology to SMN2. In addition, homologous recombination between the two genes can occur and might result in false-positive results, if positions beyond exon 7 are screened (Fig. 1) [22]. Further, a cleanup procedure for DNA from DBS had to be established and validated, addressing the questions of contamination, and intra- and interassay variability. We aimed to establish a protocol suitable to (i) extract DNA from standard DBS in a rapid way that can be used for testing in multiplex quantitative (q)PCR assays and further downstream applications, (ii) screen up to 2000 samples a day with one person operating the molecular genetic screening procedure and the least possible time occupying quantitative polymerase chain reaction (qPCR) cyclers, (iii) identify and eliminate possible sources and effects of contamination, and (iv) avoid false-positive results by optimal assay design.

In addition, we demonstrate the functionality of the protocol on over 210,000 DBS extracted and analyzed, simultaneously generating the first data for SMA in a NBS setting for a largely Caucasian population.

Materials and methods

Samples and preparation of DBS

The SMA screening has been approved by the local ethics commission (Ethics Commission No. 16125 of the Bayerische Landesärztekammer). Throughout the screening procedure, samples were mainly recruited from hospitals, with about 42% of the samples originating from the State of North Rhine Westphalia (Northwest Germany) and 58% from Bavaria (South Germany). Parents were informed and required to decide if they wanted to participate in the study. We acquired 3.2-mm punches from DBS cards (TFN, Ahlstrom-Munksjö, Bärenstein, Germany) using the Panthera Puncher 9 (Perkin Elmer, Waltham, MA, USA). To rule out the risk of a plate mixup, negative controls were used alternating between various positions on each plate. Special adaptors were required to fit 96-well semi-skirted PCR plates (4ti-0770/C, 4titude, Surrey, UK). Plates were sealed using a qPCR seal (4ti-0560, 4titude) for transport. For additional experiments, DBS was prepared and air dried for 48 h from fresh blood samples from anonymous donors.

Washing of DBS punches and DNA elution (CXCE-buffer cleanup)

All pipetting steps were performed using the ViaFlo96 system (Integra Biosciences, Zizers, Switzerland). DBS punches were incubated in 96-well plates in 50 µl of water for 10 min on a plate shaker at 200 rpm (IKA Labortechnik, Staufen, Germany); then 150 µl of CX buffer (1× PBS and 0.5% Thesit®) was added and incubated for a further 10 min on the plate shaker at ~200 rpm. After a centrifugation step (Rotanta 460, Hettich GmbH, Tuttlingen, Germany) at 1000 rpm for 5 min, the supernatant was removed with a vacuum device (VACUSAFE, Integra), and further, 150 µl of CX buffer was added. Following another centrifugation step as described above, the supernatant was removed, and 150 µl of water was added to remove residual PBS. After centrifugation and removal of the water, 50 µl of CE buffer (10 mM Tris, 0.25 mM EDTA, and 2 mM NaOH) was added to each well, and the plates were sealed using a PCR seal (4ti-0500, 4titude). The plates were then incubated in a thermal cycler (Applied Biosystems 2720, Foster City, CA) for 10 min at 92 °C.

Primers and probes

An 82-bp fragment of SMN1 exon 7 was amplified, as described by Strom et al. [23], using a slightly modified forward primer specifically targeting the SMN1 c.840C position (5′-TAT TTT CCT TAC AGG GTT CCA G-3′). A reverse primer (5′-GCT GGC AGA CTT ACT CCT TAA TTT AA-3′) and a R6G-labeled probe (5′-F-ACC AAA TCA AAA AGA AGG AAG GTG CTC ACA-Q-3′) bind to SMN1 and to SMN2. Since SMA detection is based on failure of the SMN1 exon 7 amplification, co-amplification of a reference gene is required to control the PCR reaction. The test can be combined with any genomic assay like beta-actin (TIB Molbiol 66-0913-96). For this study, a TaqMan assay for cystinosin (CTNS, OMIM# 606272) was used as control (Fleige et al., submitted) in a multiplexed qPCR. qPCR was performed in 10-µl reactions with LightCycler DNA Multiplex Master (Roche, Mannheim, Germany) in 384-well plates (Roche).

qPCR setup

qPCR reactions were set up by dispensing aliquoted primer/probe mixes and enzymes from semi-skirted PCR plates to 384-well qPCR plates using the ViaFlo96 system. Samples from the 96-well DNA plates were dispensed to the 384-well plates in a predefined manner. qPCR was performed using a 384-well block on a LightCycler 480II (Roche), with initial denaturation at 95 °C for 10 min, followed by 45 cycles in three steps at 95 °C for 5 s, 60 °C for 10 s, and 72 °C for 15 s. A single acquisition of fluorescence signals was included in the 60 °C step. Sample lists were generated from the punching log files, converted to fit the 384-well plates, and imported directly to the LightCycler.

qPCR evaluation

qPCR experiments were evaluated based on cycle quantification (Cq) applying the second derivate maximum analysis of the LightCycler software. An SMN1 gene copy was considered present, if a product was detected before cycle 36 (Cq-value < 36), while the internal control was considered present if a Cq-value < 34 was detected. If no product was visible in any assay, the result was invalid. If only the control assay showed sufficient product, the result was considered positive with the patient likely to have a homozygous deletion of SMN1 exon 7. In both cases, fresh DBS punches were retested (internal verification). In case of a verified positive result for SMA in our laboratory, parents were asked to consult a specialized treatment center (Center for Neuromuscular Disorders in Childhood at the Dr von Hauner Children’s Hospital in Munich, Neuropediatric Department of the University Hospitals of Essen, or Münster), where a blood sample was taken and sent to an independent laboratory for external confirmation of the screening result. In addition, an MLPA analysis was performed to determine SMN2 copy numbers [24].

Comparison of the CXCE-buffer cleanup with MagnaPure96 extraction

Three punches were homogenized in 600 µl of PBS using 1.4-mm zirconium beads (Precellys, Bertin Technologies, Montigny le Bretonneux, France) in a Precellys24 homogenizer. Two-hundred microliters of the homogenized punches (corresponding to one punch) were extracted and eluted in 50 µl of elution buffer on a MagnaPure96 system (Roche), using the MagnaPure small-volume nucleic acid extraction kit. One punch was subjected to the CXCE-buffer cleanup. Extractions were performed in eight replicates.

DNA quality and quantity were assessed based on the sample’s performance in the SMA assay on the LightCycler and further routine assays (supplementary material).

Robustness

Robustness of the DNA elution method was addressed by retesting samples that had been tested invalid for the internal control (Cq > 34) in the first qPCR during our routine screening. We collected 35 of such DNA samples from 4 consecutive weeks and repeated the qPCR.

Evaluation of cross-contamination and precision

We aimed to identify possible contamination sources, i.e., the punching process or the reusing of pipette tips during the different washing steps. The punching procedure was analyzed by punching from empty cards and cards prepared with blood in an alternating manner. A 96-well PCR plate was filled with punches according to the following pattern: column A-empty; column B-blood; column C-empty, etc. For one plate, the automated (plate A) Panthera Puncher 9 was used; the other plate was punched manually (plate M), avoiding all possible contamination by punching the empty cards first and then the cards containing blood. For DNA preparation, fresh pipette tips were used for every step for plate A, including removal of the supernatant. According to the routine procedure, pipette tips were not changed during the washing steps for plate M. Extracts were analyzed using the SMA test.

All DBS punches were prepared from the identical DBS; thus, the values are also representative for intra- and interassay variability.

Statistics

Cq-values are presented as means ± standard error of means (SEM). The statistical significance (p < 0.05) of the differences between the experimental groups was tested using the t test, corrected according to Bonferroni–Holm [25]. Confidence interval (CI) calculations were performed using MedCalc for Windows, version 19.0 (MedCalc Software, Ostend, Belgium).

Results

Comparison of the CXCE-buffer cleanup method with MagnaPure96 extraction

MagnaPure96 extraction resulted in a slightly but not statistically significant increased amount of DNA. On average, CXCE-buffer cleanup resulted in Cq-values of 31.85 ± 0.10, which was approximately one Cq higher compared with the extraction performed on a MagnaPure96 (30.90 ± 0.07; Fig. 2).

Fig. 2
figure 2

Performance comparison of the CXCE-buffer cleanup vs. extraction of nucleic acids on a MagnaPure96. The amplification curves show the performance of nucleic acids of both extraction methods from the same sample (gray lines: MagnaPure96 extraction, black lines: CXCE-buffer cleanup) in the SMN1 exon 7 deletion qPCR

Robustness

Altogether, no sample has been reported invalid so far, as in all cases of invalid results, processing of a fresh DBS delivered valid results. However, to elucidate the reason of invalid results in the first assessment, 35 samples have been collected over 4 weeks, showing an invalid result. qPCR was repeated using the original DNA. Out of these 35 DNA samples, only one delivered an invalid result. This suggests that incorrect pipetting in the PCR setup or incomplete sealing of the qPCR plate led to invalid results rather than a failure of the cleanup procedure.

Evaluation of cross-contamination and precision

All DBS punches were detected with Cq-values ranging from 30.73 to 32.96 on both plates. Plate A (automated punching) and Plate M (manual punching) had several wells with empty punches that displayed a late Cq (Cq > 37) in the SMA test. Plate A showed late Cqs in more negative wells than Plate M (46% vs. 13%, respectively; Fig. 3). This indicates that automated punching is the main source of contamination. Variability shows a Cq of 31.36 ± 0.09 for 40 intra-assay technical replicates and 31.84 ± 0.05 for another 40 intra-assay technical replicates, reflecting an average variability below 1 Cq for 40 replicates each. Thus, reproducibility is given for all samples (N = 80; sensitivity = 1, 95% CI = 0.91; specificity = 1, 95% CI = 0.91).

Fig. 3
figure 3

Schematic contamination patterns on a 96-well plate. Plate A shows the results of automated punching, Plate M from manual punching with white wells: no amplification, black wells: expected amplification, and gray wells: late amplification, i.e., contamination including the respective Cq-values

Newborn screening

To establish the SMN1 assay, blood samples from known SMA patients (N = 13) and a subset of their parents (heterozygous carriers; N = 8) were analyzed. In addition, the samples were distributed on DBS cards and tested thereafter. All patients were identified as carrying the homozygous deletion, while the parents showed Cq < 36 for SMN1 in the qPCR test (N = 21; sensitivity = 1, 95% CI = 0.75; specificity = 1, 95% CI = 0.63).

The NBS for SMA started mid-January 2018. So far, 213,279 DBS have been analyzed for a homozygous deletion of exon 7 of SMN1. Thirty samples showed amplification of the reference gene, but no amplification of SMN1; thus a homozygous deletion of exon 7 (N = 213,279; sensitivity = 1, 95% CI = 0.88; specificity = 1, 95% CI = 1). All 30 cases identified were referred to a neuropediatric center for consultation and were retested for the exon 7 deletion and their copy numbers of SMN2. Our primary screening results were confirmed in all cases by MLPA analysis from fresh blood samples in an independent laboratory (Genetikum, Neu-Ulm, Germany). The copy numbers for SMN2 varied between 2 and 4 (Vill et al., submitted). To date, no false-positive results have been observed; no false-negative results have been reported to us either. To date, we have determined the status of all samples from the original DBS, without any sample reported invalid.

Discussion

SMA is the second most common autosomal recessively inherited disease in humans after cystic fibrosis [26]. To include this life-threatening condition in NBS, we developed an efficient genetic screening procedure.

We established a rapid and inexpensive method implemented in a workflow that allowed us to screen a high number of samples in the shortest possible turnaround time (within 24 h per sample).

Our CXCE-buffer cleanup procedure resulted in eluates containing enough DNA for retesting, or further genetic assays like severe combined immunodeficiency (SCID), with no special reagents or commercial kits required. We limited the risk of sample mixups, a common pitfall in laboratory medicine [27], by keeping the DBS punches in the same well of a 96-well plate from arrival of the samples to the setup of the qPCR assays.

Our study showed storage conditions of NBS cards did not affect the quality of results. Automated punching of DBS is commonly used in NBS. We demonstrated that trace amounts of DNA are transferred into neighboring wells of a 96-well plate, and that this could not be avoided without any additional laborious and time-consuming steps. Thus, the typical range for Cq-values had to be established in the first qPCR assays and confirmed during validation to determine the appropriate cutoffs for late Cq-values. This was straightforward for the SMN1 assay, since a Cq difference ≥3 was detected between contaminations and heterozygous or homozygous wild-type samples.

Our results show the importance of considering the contamination problem of automated punching for genetic screening procedures.

The CXCE-buffer cleanup delivered reliable results from qPCR reactions and for further molecular genetic approaches. The number of samples requiring repeated testing due to technical errors was very low (<1%). Repeated cleanup and qPCR from fresh DBS resolved the error in all cases; therefore, no invalid result had to be reported. In addition, the data for intra- and interassay variability showed stable reproducibility of the results. Using the MagnaPure96, an automated, costly, and time-consuming extraction system, the DNA yield was only slightly higher. The CXCE-buffer cleanup is an easy DBS cleanup procedure that can be used for various assays. Combining the cleanup with a 384-well qPCR setup, limited the required qPCR capacity to one cycler; thus, over 1000 reactions could be processed in three runs in <5 h.

Among others, Saavedra-Matiz et al. described a similar method for DNA cleanup [28]. The same protocol was applied for a pilot- screening study of SMA in the New York state [29]. Many other well-designed studies dealt with DNA extraction for NBS, but have not described the screening of a large population subset or a complete setup for routine screening from punching to qPCR [13, 28, 30, 31].

Prior et al. described two pilot studies for SMA NBS, giving detailed instructions for sample handling, but limited to a commercial kit for DNA cleanup and to a 96-well format [13]. Taken together, none of the previous studies described a procedure that can be reproduced in a 384-well format.

Few other large-scale genetic NBS projects have been published so far; among others, a study of genetic screening for hearing loss assessing three simple nucleotide variants and a single-base deletion in over 140,000 samples. Genetic screening for hearing loss was implemented to increase the sensitivity of the physical test for hearing loss [32].

A study from Taiwan described the screening of 120,267 newborns for SMA. Within 22 months, 15 potential cases were identified, where eight turned out to be false positive. The introduction of a second-tier digital droplet (dd)PCR assay was necessary to accurately diagnose SMA from DBS without false positives. In the Taiwanese study, the SMN1-specific c.888+100A site was targeted for screening. However, in two cases, the targeted site was homozygous c.888 +100A>C; therefore, no product was visible. In five further cases, the SMN1 gene sequence was converted to SMN2 after the c.840C site [22]. Targeting the c.840C site eliminates these possibilities of receiving false-positive results and avoids second-tier testing [23, 33] for NBS, while still detecting only homozygous deletions, i.e., affected newborns.

With our protocol, we were able to screen 213,279 samples from routine NBS within 18 months. Thus, we provide the first unbiased population-based screening for SMN1 exon 7 deletions for a Caucasian population. Based on the described incidence of the disease between 1:4000 and 1:10,000, 20-50 cases were expected for 200,000 samples. In fact, we found 30 cases with all cases confirmed by an independent laboratory from fresh blood samples (100% positive predictive value). Unknown or de novo variants in the primer and probe sequences remain as risk for false-positive results. No missed patients have been reported to us to date (sensitivity: 100%; Vill et al., submitted). However, we expect to encounter false-negative results in the future, as other pathogenic variants are not detected with this assay design. This would affect ~3-5% of SMA cases [12].

MLPA analysis or digital droplet PCR for determination of SMN2 copy number seems to be feasible from newborn blood spots in a two-tier protocol. However, with this lethal condition, it is mandatory to confirm the first result from a fresh blood sample. This confirmatory testing including copy number determination was performed in the independent laboratory. SMN2 copy numbers varied between 2 and 4 for the identified patients. Disease severity has been shown to correlate with SMN protein levels, and SMA Type 0, I, II, or III has shown a significant correlation to SMN2 copy number. In one study, 96% of individuals with Type I carried one or two SMN2 copies, whereas 100% of individuals with Type III carried three or four copies [9]. However, the SMA degree type does not show a complete correlation with the copy numbers of SMN2 being present [16], as variants other than the aforementioned deletion of exon 7 may contribute to different phenotypic outcomes. Discordances have been reported in the patients with 3-4 copies of SMN2, who may develop SMA Type I, II, or III or rarely remaining even asymptomatic [9, 34, 35]. Recently, a therapy (Nusinersen (SpinrazaTM)) for SMA has been approved by health authorities (U.S. Food and Drug Administration (FDA): December 2016, European Medicines Agency: May 2017). Notably, Nusinersen is among the first four therapeutics licensed for clinical use, based on antisense oligonucleotides [36]. Application results in more of the SMN2 full-length transcript, which compensates for the loss of SMN1. All identified patients from this study were consulted by clinicians, with treatment advised to all patients, with two or three copies of SMN2 [37].

Other therapeutics are still in clinical phase 1 or 2 trials, with another therapy (AVXS-101) aiming to replace SMN1 [38]. SMA has been added to the Recommended Universal Screening Panel in the United States for NBS as of July 2018. Genetic screening is already offered in some countries/states for SCID screening. From a purely technical point of view, it is not a classical genetic screening, as no DNA sequence data are revealed. SCID is a disorder of (T-cell) lymphocyte formation, where in affected patients, no formation of the so-called T-cell receptor excision circles takes place. However, these DNA circles are found in healthy individuals, where they can be detected. Combined assays for SMA and SCID have already been tested in previous studies [30]. With the screening for SMA and SCID, we are at the dawn of a new era of primary DNA-based NBS. However, to screen for multiple loci will require further development in the field.