Abstract
The present study examines the performance of the ambulatory blood pressure monitor PHYSIO-PORT UP in pregnant and preeclamptic women. The systolic blood pressure (SBP) and the diastolic blood pressure (DBP) of 33 subjects (among them 13 with preeclampsia) were sequentially measured and compared to reference measurements. Those reference measurements were taken by two observers using a mercury sphygmomanometer. Subject recruitment and evaluation of the measurement results were performed according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP 2010). Three readings were recorded per subject under static conditions. The protocol did not include testing under ambulatory conditions. 87/90 (SBP/DBP) of the 99 readings had a difference ≤ 5 mmHg, 96/98 had a difference 98 ≤ 10 mmHg, and 98/99 had a difference ≤ 15 mmHg. 2 out of 3 readings ≤ 5 mmHg was achieved by 31/32 subjects. None of the subjects had less than 1 comparative reading ≤ 5 mmHg. In conclusion, the PHYSIO-PORT UP fulfilled all requirements of the ESH-IP 2010. According to these results, the PHYSIO-PORT UP can be recommended for blood pressure measurement in pregnant women.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 digital issues and online access to articles
$119.00 per year
only $9.92 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
O’Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15:23–38.
Abou-Dakn M, Döhmen C, Wenzel S. Validation of the TONOPORT VI ambulatory blood pressure monitor in adults according to the European Society of Hypertension International Protocol revision 2010. J Hum Hypertens. 2017;31:89–92.
Acknowledgements
PAR Medizintechnik GmbH & Co. KG funded this study and supplied a PHYSIO-PORT UP device free of charge for the purpose of this study.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Abou-Dakn, M., Wenzel, S. Validation of the PHYSIO-PORT UP ambulatory blood pressure monitor in pregnant women according to the European Society of Hypertension International Protocol revision 2010. J Hum Hypertens 32, 770–774 (2018). https://doi.org/10.1038/s41371-018-0101-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41371-018-0101-y
This article is cited by
-
Hypertension in Women Across the Lifespan
Current Atherosclerosis Reports (2021)