Abstract
To assess the reproducibility of nocturnal blood pressure (BP) during sleep as measured using a self-measurement device at home, we obtained repeated nocturnal home BP at 0200 h and quality of sleep assessment from a diary in 556 subjects (71% women, 62.4±11.1 years) in the general population. We used an Omron device (HEM-747IC-N, Omron Healthcare Co., Ltd., Kyoto, Japan), with which the time and frequency of monitoring can be preset and the readings stored. The mean±SD of the difference between test-retest BP measurements was 0.7±15.1 mmHg systolic and 0.2±9.7 mmHg diastolic with a mean interval of 5.9 days. The absolute differences were greater than 10 mmHg in 261 (46.9%) subjects for systolic and 145 (26.0%) subjects for diastolic. There was no evidence of regression to the mean in nocturnal measurements over at least three nights (n=390, p>0.22). The differences (the first minus the second measurement) were large in subjects who experienced sleep disturbance only in the first (n=64, 2.3±13.6 mmHg and 1.6±9.6 mmHg for systolic and diastolic, respectively) or second sessions (n=56, −4.1±16.4 mmHg and −2.5±11.4 mmHg) compared with the subjects without sleep disturbance (n=66, 1.5±17.8 mmHg and 0.8±10.3 mmHg) and those with sleep disturbance (n=370, 0.9±14.5 mmHg and 0.2±9.3 mmHg) in both sessions. In conclusion, the reproducibility of single nocturnal BP as assessed using a self-measurement device at home was not good, especially for subjects who experienced different quality of sleep in each session. To evaluate nocturnal BP using a self-measurement device, estimation of quality of sleep is indispensable.
Similar content being viewed by others
Article PDF
References
Millar-Craig MW, Bishop CN, Raftery EB : Circadian variation of blood-pressure. Lancet 1978; 1: 795–797.
Imai Y, Abe K, Munakata M, et al: Circadian blood pressure variations under different pathophysiological conditions. J Hypertens Suppl 1990; 8: S125–S132.
Mann S, Altman DG, Raftery EB, Bannister R : Circadian variation of blood pressure in autonomic failure. Circulation 1983; 68: 477–483.
Akashiba T, Minemura H, Yamamoto H, Kosaka N, Saito O, Horie T : Nasal continuous positive airway pressure changes blood pressure “non-dippers” to “dippers” in patients with obstructive sleep apnea. Sleep 1999; 22: 849–853.
Kobrin I, Oigman W, Kumar A, et al: Diurnal variation of blood pressure in elderly patients with essential hypertension. J Am Geriatr Soc 1984; 32: 896–899.
Shimada K, Kawamoto A, Matsubayashi K, Nishinaga M, Kimura S, Ozawa T : Diurnal blood pressure variations and silent cerebrovascular damage in elderly patients with hypertension. J Hypertens 1992; 10: 875–878.
Bianchi S, Bigazzi R, Baldari G, Sgherri G, Campese VM : Diurnal variations of blood pressure and microalbuminuria in essential hypertension. Am J Hypertens 1994; 7: 23–29.
Verdecchia P, Schillaci G, Guerrieri M, et al: Circadian blood pressure changes and left ventricular hypertrophy in essential hypertension. Circulation 1990; 81: 528–536.
O'Brien E, Sheridan J, O'Malley K : Dippers and non-dippers. Lancet 1988; 2: 397.
Staessen JA, Thijs L, Fagard R, et al: Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension. Systolic Hypertension in Europe Trial Investigators. JAMA 1999; 282: 539–546.
Ohkubo T, Hozawa A, Yamaguchi J, et al: Prognostic significance of the nocturnal decline in blood pressure in individuals with and without high 24-h blood pressure: the Ohasama study. J Hypertens 2002; 20: 2183–2189.
Chonan K, Kikuya M, Araki T, et al: Device for the self-measurement of blood pressure that can monitor blood pressure during sleep. Blood Press Monit 2001; 6: 203–205.
Imai Y, Satoh H, Nagai K, et al: Characteristics of a community-based distribution of home blood pressure in Ohasama in northern Japan. J Hypertens 1993; 11: 1441–1449.
Bortolotto LA, Henry O, Hanon O, Sikias P, Mourad JJ, Girerd X : Validation of two devices for self-measurement of blood pressure by elderly patients according to the revised British Hypertension Society protocol: the Omron HEM-722C and HEM-735C. Blood Press Monit 1999; 4: 21–25.
Imai Y, Munakata M, Hashimoto J, et al: Age-specific characteristics of nocturnal blood pressure in a general population in a community of northern Japan. Am J Hypertens 1993; 6: 179S–183S.
Imai Y, Nishiyama A, Sekino M, et al: Characteristics of blood pressure measured at home in the morning and in the evening: the Ohasama study. J Hypertens 1999; 17: 889–898.
Imai Y, Otsuka K, Kawano Y, et al: Japanese Society of Hypertension (JSH) Guidelines for Self-Monitoring of Blood Pressure at Home. Hypertens Res 2003; 26: 771–782.
Japanese Society of Hypertension : Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2004). Hypertens Res 2006; 29 ( Suppl): S1–S105.
Bland JM, Altman DG : Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307–310.
Chobanian AV, Bakris GL, Black HR, et al: Seventh report of the Joint National Committee on Prevention, Detection and Evaluation, and Treatment of High Blood Pressure. Hypertension 2005; 42: 1206–1252.
Staessen J, Bulpitt CJ, O'Brien E, et al: The diurnal blood pressure profile. A population study. Am J Hypertens 1992; 5: 386–392.
van der Steen MS, Lenders JW, Graafsma SJ, den Arend J, Thien T : Reproducibility of ambulatory blood pressure monitoring in daily practice. J Hum Hypertens 1999; 13: 303–308.
Thijs L, Amery A, Clement D, et al: Ambulatory blood pressure monitoring in elderly patients with isolated systolic hypertension. J Hypertens 1992; 10: 693–699.
Palatini P, Mormino P, Canali C, et al: Factors affecting ambulatory blood pressure reproducibility. Results of the HARVEST Trial. Hypertension and Ambulatory Recording Venetia Study. Hypertension 1994; 23: 211–216.
Mancia G, Omboni S, Parati G, Trazzi S, Mutti E : Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs. J Hypertens 1992; 10: 1531–1535.
Somers VK, Dyken ME, Mark AL, Abboud FM : Sympathetic-nerve activity during sleep in normal subjects. N Engl J Med 1993; 328: 303–307.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hosohata, K., Kikuya, M., Ohkubo, T. et al. Reproducibility of Nocturnal Blood Pressure Assessed by Self-Measurement of Blood Pressure at Home. Hypertens Res 30, 707–712 (2007). https://doi.org/10.1291/hypres.30.707
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1291/hypres.30.707
Keywords
This article is cited by
-
Relationship between home blood pressure and vascular function in patients receiving antihypertensive drug treatment
Hypertension Research (2019)
-
Diurnal blood pressure changes
Hypertension Research (2018)
-
Randomized trial comparing the velocities of the antihypertensive effects on home blood pressure of candesartan and candesartan with hydrochlorothiazide
Hypertension Research (2015)