Introduction

Biaxial phacoemulsification, also known as microincisional cataract surgery (MICS), is a step forward in the evolution of cataract surgery, aiming to reduce the incision size to a minimum. This technique has several advantages, including improved fluid dynamics, associated with enhanced manoeuvrability; eg, the ability to interchange the irrigation and aspiration tips.1, 2, 3, 4 In addition, surgery can be performed through incisions of 1.4 mm,5, 6 or even through a 0.9 mm incision,1 hence inducing less postsurgery astigmatism than conventional coaxial phacoemulsification (CP).5, 6

It is well recognized that in CP, temporal clear corneal incisions (CCI) induce the least astigmatism. The ophthalmic literature estimates that the magnitude of surgically induced astigmatism (SIA) studied by vector analysis is around 0.44 D and 0.88 D, rising as the size of the incision increases.7, 8, 9, 10, 11, 12, 13 When the axis of the SIA was studied, it was observed that temporal incisions induced ‘with the rule’ astigmatism.8, 10, 11

In this study, we aim to show whether or not MICS generates less astigmatism than CP with temporal incision. We studied astigmatism through three different methods:14, 15, 16, 17, 18 arithmetic, polar, and vector analysis.

Patients and methods

Participants in this study were patients who were scheduled for elective cataract surgery. The local independent ethics committee approved the study protocol, and informed consent was obtained from each patient before being enrolled in the study. Exclusion criteria were: topographic astigmatism >2.0 D, intraoperative use of corneal sutures, or corneal disease.

Ninety-four eyes of 64 patients (40 women and 24 men) with visually significant cataracts were enrolled in a prospective randomized controlled double-blind clinical trial to have CP with a temporal CCI or MICS; 43 eyes underwent CP and 51 received MICS. Neither the patient nor the examiner knew which technique had been applied.

The following examinations were performed preoperatively: measurement of best-corrected visual acuity (BCVA) using Snellen charts; slit-lamp biomicroscopy, including evaluation of nuclear lens opacity with the lens opacities classification system III (LOCS III) described by Chylack et al,19 measurement of intraocular pressure (IOP), examination of the retina, and evaluation of astigmatism by corneal topography (Zeiss-Humphrey, CA, USA).

All the operations were performed by a single surgeon (RM) under topical anaesthesia, using a two-step, self-sealing, 2.8 mm temporal CCI in the CP group. Two superior CCI were made at 135° and 45° meridians, using a trapezoidal steel keratome (Nanoedge, Geuder, Heidelberg, Germany). This forms a tunnel of 1.5 mm width in the endothelial area, and of 2.0 mm width in the epithelial surface (Figure 1). In the CP group, the intraocular lens (IOL) Y601075 (AJL, Álava, Spain) was injected. This IOL consists of a single piece hydrophilic acrylic lens with plate haptics, a total diameter of 10.75 mm and 6 mm optic. The acrylic Acri Smart 48S IOL (Acri.Tec, Hennigsdorf, Germany) was implanted through the 135° clear corneal incision in the MICS group by intraocular injection. This lens is a one-piece foldable acrylic IOL with 25% water content in a fully hydrated state and with hydrophobic surfaces. It has a 5.5 mm optic with a total diameter of 11 mm. Despite its standard thickness, the lens permits an injection through a 1.5 mm incision because of its special design using the Acri.Smart system. This system includes an Acri.Glide cartridge and a custom-designed injector.

Figure 1
figure 1

Location of incisions: oblique superior CCI in the MICS group, temporal CCI in the CP group; RE: right eye, LE: left eye.

At 1, 3, and 6 months after surgery, BCVA was measured and astigmatism was evaluated by corneal topography. Astigmatism was studied using the following methods:14, 15, 16, 17

  1. 1)

    Arithmetic analysis, or simple subtraction, measures the amount of astigmatism before and after surgery without considering the axis.

  2. 2)

    Polar analysis establishes the steepening effect occurring in the reference meridian located at 90°. The obtained parameter is called the vector polar net-induced value (VPNIV). A positive value indicates a ‘with the rule’ change in astigmatism, while a negative value illustrates an ‘against the rule’ change. An increase in magnitude of SIA is associated with a rise in VPNIV. This parameter accounts at the same time for the amount of change and angle of change.18

  3. 3)

    Vector analysis. SIA is defined by a module and a direction.

To compare post-SIA, a control group was recruited including 55 healthy eyes. Topographic examination was performed once, and then repeated between 10–20 days afterwards, without any intervention in the interval. The same analysis previously described for the astigmatism was carried out again.

For evaluation of the astigmatism parameters, calculations were performed following the Alpins method,14, 15 using the Vectrak 1.4.01 program (Victoria, Australia). All numerical and graphical evaluations were performed by means of SPSS (Version 10.0 for Windows, SPSS Inc., Chicago, IL, USA).

Comparisons of the results between the different techniques were performed by means of the non-parametric Mann-Whitney U-test. Comparisons of repeated measurements in continuous endpoints were evaluated by means of the Friedman test. Qualitative measurements were studied using the χ2 test. Results of the significance tests were summarized by means of P-values. P-values indicate local statistical significance where P<0.05.

Results

The patients' mean age was 69.02 years ±8.60 in the CP group and 72.04±7.87 in the MICS group. The degree of nuclear lens opacity, according to the LOCS III classification, resulted in 2.35±0.95 and 2.43±0.90 for the first and second groups, respectively. There were no statistical significant differences in age, sex, or nuclear lens opacity between the CP and MICS groups. The follow-up time interval range was between 1 and 6 months. At 1 month, BCVA was 0.97±0.12 in the CP group and 0.93±0.17 in the MICS group; no statistically significant difference was observed between both groups. Table 1 illustrates the distribution of follow-up periods.

Table 1 Performed follow-up

Arithmetic analysis

Simple subtraction of astigmatism was 0.09±0.43 in the CP group and 0.03±0.28 in the MICS group in the first month after surgery. We found no differences between techniques when evaluating change in astigmatism using arithmetic analysis over the observational period. Mean values were all around zero with little dispersion during follow-up. The non-surgical control group showed similar results, with a change of 0.04±0.24 D, which was not statistically significant compared to both groups separately.

Polar analysis

No differences between the surgical techniques were exhibited when evaluating change in astigmatism with polar analysis. VPNIV was 0.08±0.45 in the CP group and 0.07±0.42 in the MICS group in the first month after surgery (P=0.99). Polar analysis showed again values around zero, with positive values for all follow-up MICS and CP examinations, except at 3 months for the latter. Over the following 6 months observational period, we found that there was no difference in VPNIV, considering these techniques separately. The non-surgical control group showed similar results, a VPNIV of 0.07±0.23, which was not statistically significant compared to both groups separately.

Vector analysis

SIA magnitude

The SIA magnitude computed between the first month after surgery and the successive follow-up period was around 0.5 D in both surgical groups, with little dispersion. Table 2 shows the mean SIA magnitude and the SD of both techniques during the complete follow-up period. The intergroup differences were not significant. Similarly, no significant intragroup differences were measured during the follow-up period.

Table 2 SIA module

In the non-surgical control group, the fictitious mean magnitude of the SIA was 0.31±0.27 (topographic examination had been performed once, and then repeated between 10–20 days afterwards, without any intervention in the interval). This value shows statistical significance compared to both groups separately (P=0.015 for CP and P=0.014 for MICS).

Axis of SIA

Axis distribution of SIA was quite homogeneous between all groups in the first month. However, as seen in the histograms (Figure 2), distribution around 90° was more frequently seen in CP, whereas distribution around 50° was more frequent in MICS. By the third month, these differences became more subtle.

Figure 2
figure 2

Axis distribution of the SIA vector in the first month.

Discussion

The main objective of this study was to test the significant differences in surgically generated astigmatism between two phacoemulsification techniques. Modern small-incision clear corneal cataract surgery has the benefit over older techniques of causing less SIA. The use of two incisions in MICS spaced at 90°, superonasal and superotemporal, would cancel the coupling phenomenon associated to corneal incisions. If superior and temporal incisions were performed, the former would induce a higher degree of astigmatism than the latter.

We limited our analysis to early and late surgically induced astigmatism, up to 6 months postoperation. Astigmatism was measured using the following three methods:

Arithmetic analysis showed positive values during the whole follow-up, although the values were around zero. This showed that corneal astigmatism measured by simple subtraction was negligibly augmented. No significant differences were found between the two surgical techniques.

Polar analysis showed again values around zero, with positive values for all follow-up MICS and CP examinations, except at 3 months for the latter. The positive sign in the polar analysis shows that ‘with the rule’ astigmatism is more commonly induced. Once again, no significant differences were found between the two surgical techniques.

Vector analysis in the MICS and the CP groups showed mean SIA module of around 0.5 D, with little dispersion. Both techniques were stable during subsequent follow-ups. No differences were observed between the two surgical techniques.

The amount of SIA for both surgical techniques has been shown not to be significantly different in our study. Alió et al,6 reported that MICS significantly lowered SIA, when compared with CP by vector analysis. However, their results are not comparable with those obtained in our work, due to the location of the incisions. Alió et al6 made incisions placed at the steepest corneal meridian in both techniques; however, in this study, we systematically made temporal incisions for the CP group, which has been found to induce the least surgical astigmatism. Other authors20, 21 found no difference in astigmatism with the MICS and CP groups, but results are not comparable due to the type of study design (different number, length, or localization of incisions). In common with other authors,7, 8, 9, 10, 22 we have found that the SIA magnitude remained stable during the whole analysed period.

Axis distribution of the SIA is similar and homogeneous between techniques, although there is a trend towards 90° distribution for the CP group and towards 50° distribution for MICS. An axis of SIA of around 90° was expected to occur in the CP group, since the incision was temporal. However, homogeneous axis distribution of SIA was expected for MICS, because we attempted to cancel out the coupling phenomenon by using the above-mentioned incision locations. An explanation for the finding of a higher frequency SIA located at 50° could be that during IOL introduction in the 135° meridian, the incision was forced and enlarged, which therefore produced a higher flattening effect in the 135° axis, and a higher steepening effect in the 45° axis. These could not be counteracted by the same amount of opposite astigmatism induced by the non-enlarged 45° incision. However, we did not measure the incision at the end of the procedure.

To study whether corneal topography reproducibility or spontaneous corneal changes over time might have biased our results, we performed serial topographies on a control group.

We found that there was a change in astigmatism of 0.31±0.27 in the case of unoperated eyes (the equivalent of SIA). Therefore, it is probable that the SIA found in our study in operated eyes might actually be smaller, since a remarkable change was found in non-surgical cases. Van den Dooren and Hennekes23 also observed a mean astigmatism of 0.35 D in a control group of unoperated eyes. The SD of corneal power in one point is approximately 0.2 D.24 Changes in corneal power are also affected by diurnal and nocturnal changes as well as hormonal factors, although these are generally negligible.25

MICS potentially presents better fluid dynamics than CP; bimanual and separated irrigation/aspiration functions are a safer and more comfortable procedure. Although larger studies might be necessary, we did not find significant changes in SIA when comparing MICS and CP performed at temporal incisions. We found the temporal approach in CP less comfortable for a right-handed surgeon, especially when operating on left eyes, as the seating position has to be changed, depending on the eye that is going to be operated on. New IOL technology that allows the easy introduction of such a lens through a 1 mm incision will most probably lead to a reduction in SIA in MICS.

In conclusion, the surgical techniques examined (MICS and CP) generated similar levels of astigmatism in the cornea. However, given the location of the incisions, the MICS technique can be performed by the surgeon more comfortably while positioned in the head area of the patient than when using the lateral position expected in the CP through a temporal corneal incision.