Abstract
A series of 90 eyes of 88 myopic patients who underwent extracapsular cataract surgery with intraocular lens implants (IOLs) between 1984 and 1989 were analysed in a retrospective study. The axial length as obtained by ultrasonic A scan and keratometry readings were applied to the SRK1 and modified SRK (SRK2) formulae1-3 and the result compared with the actual post-operative state achieved.
Similar content being viewed by others
Article PDF
References
Ratzlaff J, Sanders D, Kraff M : A Manual of Implant Power Calculations: SRK TM Formula. Medford, Oregon 1981.
Sanders D and Kraff M : An improvement of intraocular lens power calculation using empirical data. Am Intra-ocular Implant Soc J 1980, 6: 263–
Retzlaff J : Posterior chamber lens implant power calculations: Regression formulas. Am Intra-Ocular Implant Soc J 1980, 6: 268–
Hoffer KJ : Intraocular lens calculation: the problem of the short eye. Ophthal Surg 1981, 12: 269–
Sanders D et al: Comparison of the accuracy of Bink-horst, Colenbrander and SRK implant power prediction formulas. Am Intra-Ocular Implant Soc J 1981, 7: 337–41.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
McCormack, P., Evans, A. & Gregson, R. An analysis of the accuracy of prediction of intraocular implant power in the myopic patient. Eye 5, 63–65 (1991). https://doi.org/10.1038/eye.1991.12