Main

Monkeypox virus (MPXV) is a zoonotic virus in the family Poxviridae, genus Orthopoxvirus. It was first isolated from lesions seen among captive monkeys in Copenhagen, Denmark.1 Human monkeypox was subsequently identified in 1970 in the Democratic Republic of the Congo (DRC).2 The virus causes a disease in humans that is similar to smallpox, but results in a lower case-fatality rate. The disease is endemic in the rainforests of central and western Africa, where squirrels and monkeys have been suggested to play a role in the life cycle of the virus.3, 4, 5

With the eradication of smallpox and widespread discontinuation of smallpox vaccination, human monkeypox has re-emerged as a human health threat with major outbreaks occurring in 1996–1997 and 2001 in the DRC.6, 7 More recently, MPXV was found to be the cause of a cluster of cases of disease in the Midwest region of the US.8, 9, 10 Epidemiologic investigations confirm that the human cases of monkeypox resulted from contact with infected prairie dogs that had been housed or transported with African rodents imported from Ghana.11 This represents the first time that a monkeypox outbreak has occurred in the Western Hemisphere and highlights the need for rapid and accurate diagnostics to detect these emerging viral pathogens.

Several molecular-based techniques have been developed to detect and discriminate orthopoxviruses;12, 13, 14, 15 however, they require conventional polymerase chain reaction (PCR) followed by restriction endonuclease digestion and subsequent gel electrophoresis. Recently, rapid real-time PCR methods were developed for detecting Orthopoxvirus DNA.16, 17, 18 The goal of this study was to develop real-time LightCycler PCR assays based on the conserved F3L and N3R genes for specifically detecting MPXV and validating these assays by using a panel of DNAs from orthopox viral isolates that vary both temporally and geographically and tissues from various MPXV-infected rodents from the recent US outbreak.8 Two previously developed pan-orthopox real-time PCR assays based on the hemagglutinin (HA) and E9L genes19 and a pan-orthopox electrochemiluminescence (ECL) immunoassay were also used to evaluate potentially monkeypox-infected tissues.

Materials and methods

PCR Primers, Target Sequences, and Fluorogenic Probe

The real-time PCR assay primers and TaqMan®-MGB probe sequences are listed in Table 1. The Vaccinia F3L gene (also called the D14L gene) (GenBank Accession #'s: AF380138 for MPXV-ZRE (bp 48 048–48 509); M35027 for VAC-COP (bp 50 911–51 483); Y16780 for VMN-GAR (bp 39 619–40 197); L22579 for VAR-BSH (bp 39 258–39 836); AF482758 for CPXV-BR (bp 64 465–65 037); NC_001611 for VAR-IND (bp 38 632–39 204); AF095689 for VAC-TAN (bp 47 348–47 921); AF438165 for CMPV-M96 (bp 50 654–51 226)) and the N3R gene (GenBank Accession #'s: AF380138 for MPXV-ZRE (bp 190 003–190 733); X94355 for CPXV-BR (bp 19 910–20 625 reverse)) sequences were selected as potential monkeypox-specific targets. All sequence alignments were carried out using the EMBL-EBI ClustalW (1.82) Multiple Sequence Alignment Tool (http://www.ebi.ac.uk/clustalw/index.html). Regions of nonhomology were used as target sequences for each potential MPXV-specific assay. The specific primer and TaqMan®-MGB probe sequences were designed using Primer Express Version 2.0 for Windows (Applied Biosystems). All primers were synthesized using standard phosphoramidite chemistry with an ABI 394 DNA/RNA synthesizer. The TaqMan®-MGB probes were also synthesized by ABI and contained 6-carboxyfluorescein (6FAM) at the 5′ end. An NFQ and the MGB were added to the 3′ end.

Table 1 Primer/probe sequence of the monkeypox-specific assays

5′ Nuclease PCR (TaqMan®-MGB) Assays

Using the Primer Express 2.0. software to design potential MPXV-specific TaqMan®-MGB assays (F3L-MGB and N3R-MGB), we optimized each assay according to a standard protocol instituted by the Diagnostic Systems Division at US Army Medical Research Institute of Infectious Diseases (USAMRIID). Briefly, potential primer pairs were initially tested in the LightCycler by the fluorescent dye SYBR Green I (Roche Biochemicals). The optimum primer pair was selected based on specificity (a single, appropriately sized amplicon) and efficiency of amplification (lowest Ct value which is defined as the real-time PCR cycle at which the LightCycler software determines the reaction to be positive). The selected primer pair was then optimized to the final concentration (0.1–1.0 μM) with the lowest Ct value and the highest fluorescent signal. Next, several potential TaqMan®-MGB probes were tested with the optimized primer pair by varying the probe and MgCl2 concentrations. The final assay consisted of the primer/probe pair concentrations and reaction conditions that combined the lowest level of detection (LOD—the gene copy number that was detected by the assay at least 58/60 times), lowest Ct value, and highest fluorescent signal-to-noise ratio. The LODs of the assays were determined from serial dilutions of genomic DNA purified from monkeypox virions (Zaire 79-I-05).

All assays were carried out in 20 μl volumes for the LightCycler with each reaction made up in PCR buffer (50 mM Tris, pH 8.3); 25 μg/ml of bovine serum albumin (BSA) and 0.2 mM dinucleotide triphosphate (dNTP) mix (Idaho Technology, Salt Lake City, UT, USA). Eight-tenths (0.8) unit of Platinum Taq DNA polymerase (Invitrogen) was added to each reaction. The final MgCl2, primer and probe concentrations for each assay are listed in Table 1. Thermal cycling for the LightCycler was performed as follows: one cycle at 95°C for 2 min, followed by 45 cycles of 95°C for 1 s and 60°C for 20 s. A fluorescence reading was taken at the end of each 60°C step. Each reaction capillary tube was read in Channel 1 (F1) at a gain setting of 16 with data being analyzed by the LightCycler Data Analysis software (version 3.5.3). Sample curves were analyzed using the ‘second derivative maximum’ with the baseline adjustment set to Arithmetic.

Extended Assay Evaluation

Both assays were extensively evaluated, first against various genomic orthopox and nonorthopox virus nearest-neighbor DNAs (Table 2). The panel consisted of 17 monkeypox viral isolate DNAs (10–100 pg/μl), 25 Variola isolate DNAs (100 pg/μl), and DNAs from Vaccinia, camelpox, cowpox, Herpes simplex, Varicella zoster viruses, and human genomic DNA. Utrecht is a nonhuman primate monkeypox isolate. The other MPXV DNAs are human monkeypox isolates from Zaire/DRC; MPX-Sierra Leone is an isolate from 1970, 12003KI is an isolate from 1999 (DRC), and V96-I-16 is a strain of MPX-monkeypox Zaire. Within the MPXV panel are 11 monkeypox-human isolates obtained from clinical samples during the 1996 outbreak in the Congo (unpublished data). All testing with Variola virus genomic DNA was conducted at the Centers for Disease Control and Prevention (CDC), Atlanta, GA, USA. Both assays were also tested against various bacterial isolates and strains from the USAMRIID bacterial DNA cross-reactivity panel (100 pg of each DNA) (data not shown). In all, 5 μl of each sample was added to the appropriate MPXV assay LightCycler Master Mix (15 μl) and cycled as described above. All test runs included at least one positive control that contained 2.3 × 104 copies (5 pg total) of purified monkeypox genomic DNA (Zaire 79-I-05) and two no-template controls (NTC): reagent NTC and sample NTC.

Table 2 USAMRIID/CDC DNA panel

Study Animals

All animals used in this study were collected from either an exotic pet dealer or private homes in the Chicago, Illinois metropolitan area. The animals were voluntarily released to public health and veterinary health officials as a result of either cohabitation of these animals with known positive animals or those that exhibited signs of orthopox infection. All animals were euthanized and frozen for transport to USAMRIID. Animal species tested during the course of this study included: prairie dog (Cynomys sp.), rat (Rattus sp.), hamster (Cricetus spp.), dwarf hamster (Allocricetulus sp.), gerbil (Gerbillus sp.), Jerboa (Jaculus sp.), mole rat (Heterocephalus sp.), and chinchilla (Chinchilla sp.).

Postmortem Examination and Tissue Collection

The 52 frozen rodent carcasses (see Table 3) collected in Illinois that were linked to possible MPXV transmission were thawed overnight in a Class II laminar hood. Complete necropsies were performed on each animal by or under the direct supervision of a board-certified veterinary pathologist. Tissue samples including brain, lung, liver, spleen, kidney, and ovary/testis of each rodent, and dermal lesions with the draining lymph nodes of affected rodents were harvested for PCR, immunoassay, and viral isolation. However, not all tissues were taken from each animal.

Table 3 Animal real-time PCR

Tissue Preparation and DNA Extraction

A 10% homogenate of each tissue specimen was made in Dulbecco's high-glucose medium using a PCR tissue homogenizer (Omni International, Inc., Warrenton, VA, USA). The homogenate was centrifuged for 10 min at 2000 rpm at 4°C. DNA was extracted from 100 μl of the supernatant using the QIAamp DNA Mini kit (Qiagen, Inc., Valencia, CA, USA) according to the manufacturer's instructions with the following minor modification: during the initial lysis step, the incubation time was increased to overnight at 56°C to ensure complete lysis of any virus present in the sample. The remaining supernatant was stored at −70°C for immunoassay and virus isolation.

Inhibition Testing of Animal DNA

Inhibition testing of DNA isolated from animals was performed incorporating an internal positive control (IPC) testing system developed at USAMRIID (manuscript submitted). Briefly, both forward and reverse primer sites and a TaqMan® probe site of the Bacillus anthracis protective antigen gene was mutated to create a novel sequence with no known homology to published sequences with a resulting amplicon of 153 bp. The IPC was shown to be sensitive to a variety of inhibitors including hemoglobin, heparin, ethylenediamine tetraacetic acid (EDTA), humic acids, and fulvic acid. All extracted animal samples were tested for inhibition by adding either 5 μl of the sample to 15 μl of the same IPC LightCycler Master Mix and compared to an IPC control (5 μl of H2O instead of sample). Cycling conditions on the LightCycler were as described above. All sample curves were analyzed using the LightCycler Data Analysis software (LCDA version 3.5.3) with ‘second derivative maximum’ and baseline adjustment set to arithmetic.

Testing for inhibition with the IPC assay resulted in three possible outcomes: (a) complete inhibition; (b) partial inhibition (the cycle threshold (Ct) was delayed and/or end point fluorescence (EPF) was reduced); or (c) no inhibition (Ct and EPF were comparable to the H2O blank). A Ct shift of three cycles was quantitatively equivalent to an approximately one log decrease in copy number (detection limit). Therefore, a Ct shift of greater than three cycles beyond the water blank was considered inhibitory. Inhibition was indicated when a sample had a Ct shift of greater than three cycles OR a reduction in EPF of greater than or equal to 50% when compared to water controls. If inhibition was observed in a sample, two-fold serial dilutions were performed until inhibition was completely eliminated. Ct shifts less than three cycles or less than 50% loss of EPF were not considered significant, and dilution of these samples would unnecessarily dilute out the target DNA.

Assaying of animal tissues

Real-Time PCR (panHA-MGB, panE9L-MGB, F3L-MGB, and N3R-MGB)

Each animal tissue-extracted DNA (appropriately diluted based on the IPC assay results) was tested with four real-time PCR assays. The first two assays, panHA-MGB and panE9L-MGB, were described previously19 and detect the presence of orthopoxvirus DNAs. Each tissue DNA was then tested in singlet with the MPXV-specific assays, F3L-MGB and N3R-MGB. All resulting positive samples were then retested in triplicate. A 3/4 or 4/4 positive result on any given assay indicated that the sample was positive for either/both Orthopoxvirus DNA and/or MPXV DNA. If a sample was only 1/4 positive, the sample was called negative. If the sample was 2/4 positive, the sample was re-extracted and retested by both the F3L-MGB and N3R-MGB PCR assays. If any sample remained only ‘50% positive’, the sample result would have been labeled ‘indeterminate.’

pan-Orthopox ECL

A mixture of four monoclonal antibodies (Mab) was used as capture antibodies. An additional two Mabs were added as detector antibodies (total of six Mabs). All antibodies were originally developed against Vaccinia virus and were selected for this assay based on their ability to recognize four different Vaccinia proteins and their cross-reactivity with multiple members of the Orthopoxvirus genus including Vaccinia, monkeypox, cowpox, camel pox, Variola major, and Variola minor. These antibodies were produced in bioreactors, purified using protein G chromatography medium, and labeled with biotin or ruthenium (II) tris-bipyridal chelate (Ru) using standard coupling methods.20 Biotinylated antibodies were prebound to streptavidin-coated 2.8 μm diameter paramagnetic beads. Concentrations of labeled antibodies were then optimized as previously described.20 Finally, the optimized capture antibody-bound beads and Ru-labeled detector antibodies were mixed and lyophilized into single-use assay tubes.

The ECL Orthopoxvirus-genus detection assay was conducted as follows: 50 μl of an unknown sample (liquid) or controls were added in duplicate to tubes containing the lyophilized capture and detector antibodies. The tubes were then incubated for 15 min on the vortexing Origen® Analyzer 1.5 carousel (Igen International Inc., Gaithersburg, MD, USA) after which 300 μl of 10 mM phosphate-buffered saline with 0.3% Tween-20 (PBS-T) was added to each tube. The analyzer then drew the processed sample from the carousel to a flow cell where it captured and washed the magnetic beads and measured the ECL signal. Tissue preparations from uninfected mice and Dulbecco's high glucose medium containing 1% fetal calf serum served as matrix controls and were used to determine assay cutoffs. The data were analyzed using custom prepared Microsoft® Excel 2000 spreadsheets. Samples were considered positive if the ECL signal was greater than the average plus three times the standard deviation or 1.2 times the average ECL signal of the negative matrix controls, whichever was higher. Differences in ECL signals of the various machines was negated by determining the S/N ratio of each sample, calculated by dividing the sample ECL value by the average ECL value of the negative matrix controls. Positive controls near the sensitivity level of the assay were included on every run. The assay could detect as little as 5 × 105 plaque-forming units (PFU)/ml or 2.5 × 104 PFU per assay of Vaccinia virus and was quantitative within a dynamic range of at least 2.5 logs of virus. The size of the dynamic range and sensitivity level varied slightly depending on the Orthopoxvirus strain tested. The assay was not used in a quantitative manner for this work. The total assay time is 15 min plus up to 1 min per sample reading time.

Results

Development of Assays

The final primer/TaqMan®-MGB probe assay sequences and reaction conditions for each MPXV-specific assay are shown in Table 1. The pan-orthopox assays (panHA-MGB and panE9L-MGB) were previously published.19 The MPXV assays reproducibly detected 11–55 fg of monkeypox genomic DNA, which represented approximately 50–250 copies of each gene. Results from the genomic DNA LOD experiments also correlated linearly with a dynamic range of six orders of magnitude representing approximately 25 to 2 500 000 copies (data not shown).

USAMRIID/CDC DNA Panel Evaluation

Both MPXV-specific assays were tested against two DNA panels: (1) a USAMRIID/CDC orthopox DNA panel (Table 2) and the USAMRIID DNA cross-reactivity panel (99 DNAs—data not shown). The results in Table 2 indicate that both the F3L-MGB and N3R-MGB assays were capable of detecting all of the MPXV genomic DNA species available in the orthopox DNA panel. Non-MPXV DNAs (to include human DNA, 25 strains of Variola virus DNA, five strains of Vaccinia, camelpox, cowpox, fowlpox viruses, two strains of Herpes simplex virus, and three strains of Varicella virus) were not detected by either assay. There were no false positives among the non-MPXV DNA samples for either of the assays on the LightCycler. Data from the USAMRIID bacterial cross-reactivity panel demonstrated that both assays were also negative (not detected) for 99 different isolates and strains of bacterial DNA.

Animal Results

A total of 52 animals were screened for the presence of orthopox DNA using the two previously tested orthopox spp-MGB assays: panHA-MGB and panE9L-MGB.19 The sensitivities of the panHA-MGB and panE9L-MGB were retested with monkeypox DNA. The LODs for both assays was 2.5 fg (12 copies). The animals were also tested for the presence of monkeypox DNA using the F3L-MGB and N3R-MGB assays. Results (Table 3) indicate that a total of 12 out of the 52 animals had at least one tissue PCR positive for MPXV DNA.

Table 4 shows the results of testing 318 total tissue samples from the 52 animals. Note that some tissues (particularly from the prairie dogs) exhibited some level of PCR inhibition. The inhibition was overcome by diluting the sample 1:2, 1:4, or 1:8 with the dilution selected, which restored the Ct values when compared to the noninhibited control. The total positives for one or more PCR assays were 25 tissues from 12 different animals (Table 5). The ECL data are also presented in Table 5. In all, 12.6% of all tissues exhibited some level of PCR inhibition. However, the vast majority (75%) of PCR-inhibited tissue samples were from prairie dogs. We attribute this fact to the possible way the prairie dogs were handled both before and during shipment to USAMRIID. Also noted during virus culture was the fact that the prairie dog tissues were highly contaminated with bacteria that may have contributed to the PCR inhibition. Table 5 shows the breakdown of each positive animal, which tissue was positive, and the results of the individual PCR and ECL tests. All other tissue samples (a total of 292 with the exception of the spleen of gerbil #32, which was PCR-negative but ECL-positive) were negative for all four PCR tests. An additional 17 tissues from randomly chosen PCR-negative animals were also negative for ECL (data not shown). Animals testing positive for all four PCR assays (in at least one tissue) were 7/12 (58%) of positive animals or 7/52 (15% of all animals tested). Animals testing positive for at least three PCR assays (in at least one tissue) were 10/12 (83%) of positive animals or 10/52 (19% of all animals tested). Animals testing positive for at least two PCR assays (in at least one tissue) were 10/12 (83%) of positive animals or 10/52 (19% of all animals tested). Animals testing positive for only one PCR assay (in at least one tissue) were 2/12 (17%) of positive animals or 2/52 (3.8% of all animals tested). Interestingly, there was only one case where a tissue (liver of hamster #21) was positive for panHA-MGB but not positive in either MPXV assay. This tissue was also ECL positive. We, therefore conclude that all virus detected by PCR was MPXV and that the liver tissue from hamster #21 contained MPXV virus DNA very near the detection limit of our four PCR assays. It is also possible that the tissue may have been infected by some other orthopox virus (ie, ectromelia).

Table 4 Animal tissue real-time PCR assays
Table 5 Positive animal tissue assays

All eight tested tissues from prairie dog #8 tested positive by PCR. Three of these tissues were also ECL positive. This animal was therefore chosen for culture attempts of the virus (specifically the skin and lung tissue) because they had the lowest PCR Ct values indicating that they potentially contained the highest concentration of viable virus.

DNA Sequencing

The 139 and 107-bp amplicons produced from the MPXV-specific N3R and F3L assays, respectively, were sequenced and compared to related orthopoxviruses in GenBank. When aligned to other MPXV sequences, using BLASTN, both amplicons exhibited 100% identity to the Zaire-96-I-16 strain of MPXV (data not shown).

Discussion

In the United States, smallpox vaccinations were discontinued after the eradication of the disease in 1979. However, recent world events have prompted the US military to begin vaccinating troops against smallpox. The anthrax attacks during the fall of 2001 demonstrate that there is a high potential for additional bioterrorism attacks. It is conceivable that an individual or possibly a rogue government could use their technical expertise to mass-produce an infectious Orthopoxvirus such as smallpox or MPXVs (or a genetically engineered variant of either). It is, therefore, crucial that fast, reliable yet simple molecular diagnostic tests be developed with the latest detection and identification technology available. We present the development and extended evaluation of two real-time PCR assays to confirm the presence of monkeypox DNA (MPXV-specific assays) on the LightCycler. Each assay is an entirely new assay (F3L-MGB or N3R-MGB) incorporating MPXV-specific target sequences. The primers were specifically designed to generate amplicons less than 150 bp because these assays were to be used in a rapid cycling machine (one cycle/15–20 s). We chose primer/TaqMan®-MGB probe pairs that exhibited the maximum efficiency of amplicon synthesis, the lowest Ct value, and the maximum LOD. We opted to use TaqMan®-MGB probe technology because it possesses significantly improved hybridization properties.21 TaqMan®-MGB probes are more stable, display increased mismatch discrimination, and have an improved S/N ratio due to the use of an NFQ instead of the fluorescent quencher dye TAMRA.22 In addition, the MGB stabilizes A/T rich duplexes, resulting in increased probe Tm (that temperature at which 50% of an oligonucleotide is annealed to its complement strand). Therefore, the MGB probes simplified assay design for the MPXVs, which have a high A/T ratio (66%).23

In this study, the LOD for each TaqMan®-MGB assay was evaluated on the LightCycler using purified monkeypox (Zaire 79-I-05) virus genomic DNA. The LOD with genomic DNA was 11–55 fg (50–250 copies). Both assays were also highly quantitative over a range of 1 ng (5 × 106 copies) to 11 fg (50 copies) when tested in the LightCycler. Initial testing against genomic DNAs available at USAMRIID and from the CDC increased our confidence in the overall specificity of each assay. While each assay detected only the appropriate DNA samples in the USAMRIID/CDC orthopox DNA panel, none of the assays detected any DNAs in the cross-reactivity panel. These data showed that both MPXV-specific TaqMan®-MGB assays were highly specific and exceptionally sensitive.

The MPXV-infected animal results presented in this study confirm that both previously reported pan-orthopox assays19 along with the two new MPXV-specific assays (F3L-MGB and N3R-MGB) achieve the same level of sensitivity and specificity with clinical (animal) samples as they do with pure cultures. Of the 52 animals ultimately tested, 12 were shown to have at least one tissue positive for MPXV DNA with one animal positive for all eight of its tissues tested. ECL testing of this same animal's tissues showed that only three of the PCR-positive tissues were ECL-positive. This result is not surprising for two reasons: ECL for orthopox viruses has been shown to be less sensitive than PCR (ECL limit of detection for the orthopox viruses is approximately 5 × 105 PFU/ml or 2.5 × 104 PFU/assay); secondly, we were not able to detect monkeypox virions by electron microscopy and no viable virus was isolated from the PCR-positive skin and lung tissue of prairie dog #5. These observations suggest that viral loads were either present at concentrations below the LOD of these techniques or samples were degraded such that antigen was not available in a form that could be recognized by the antibodies used in the ECL assay. Spleen from one animal was ECL-positive but PCR-negative. This result is at present not understood but could represent a false-positive ECL result or a false-negative PCR result. Alternatively, it is possible that viral antigen could have been present in the absence of agent-specific nucleic acid.

Sequencing of the PCR products obtained from the MPXV-infected tissues revealed a 100% identity with the Zaire 96-I-16 strain of MPXV. This strain was originally isolated from an infected human during the 1996 outbreak in the Democratic Republic of Congo (formerly Zaire).24, 25 It is known that two clades of MPXV exist in Africa, those isolated from Zaire and those from West Africa (H Meyer, personal communication). As the source of this outbreak was from rodents collected from Ghana in West Africa, we presumed that they carried viruses of the West African clade. It is possible, although highly unlikely, that our samples and/or PCRs were contaminated with MPXV strain Zaire 96-I-16. We do not believe this to be the case for several reasons. First, testing of additional samples from this outbreak, which were processed independently by the Poxvirus Section at the CDC, yielded PCR products that also exhibited 100% identity to the Zaire 96-I-16 strain. Second, although our laboratory possesses the Zaire 96-I-16 strain of MPXV, it had not been worked with or grown in the laboratory in over 2 years, and it was not used as positive control DNA for any of the PCR assays used in this study. Another, more likely possibility, is that either the size of the amplicons sequenced, or the specific gene targets themselves (ie, F3L and N3R) do not allow for differentiation of the two clades. In support of this idea, Reed et al10 recently showed that the sequence of a PCR amplicon, using the HA gene as a target, from a patient and a prairie dog from the 2003 outbreak grouped within the West African clade. Complete genome sequencing of isolated virus will be needed to resolve these issues.

In addition to using these assays for diagnostics during an outbreak, they have potential uses in monitoring viral-load in real-time in animal models of Orthopoxvirus disease. For example, Jahrling and colleagues recently developed a monkey model for studying the progression of smallpox infections.26 In these studies, our quantitative pan-orthopox HA-MGB assay was used to monitor viral load in monkey blood and tissues after infection with smallpox virus. Smallpox infections in monkeys are an important surrogate model for human smallpox infections.27 Likewise, the two MPXV-specific assays reported here could be used to monitor, in real time, the progression of monkeypox in nonhuman primates as has been done in smallpox animal models (unpublished data).

In conclusion, this study demonstrates the reliable and specific identification of MPXV virus DNA from clinical (animal) samples by TaqMan®-MGB real-time PCR on the LightCycler. By using these assays as part of a battery of PCR and ECL tests, one can first establish the presence of orthopox viral DNA and/proteins in a sample. Then MPVX can be quickly and accurately distinguished from smallpox virus by the use of the MPXV-specific PCR confirmatory assays in conjunction with three previously published smallpox-specific assays.19