Abstract
WE have carried out differential thermal analyses of beryllium oxyacetate in order to find accurate transition and melting points and also to examine the heat effect associated with these (Fig. 1). The observed transition and melting points are 148º C. and 286.7º C., respectively. If the sample is heated up to about 250º C. and then cooled to the room temperature, there is observed no transition phenomena in the cooling curve; this behaviour persists, for no transition phenomena is shown by the heating curve obtained on the next day (see curve II). But, when the sample is not heated beyond about 210º C., the transition in the heating curve made on the next day is always observed. The velocity of transition is accelerated by grinding the supercooled sample in an agate mortar. But this effect is somewhat complex. Details of the observation will be reported elsewhere. Comparison of the two peaks in the curves of the thermal analysis reveals that the heat of transition is nearly equal to the heat of fusion.